Air PurifiersMedium Room
Honeywell HPA6000B Air Purifier Manual
Setup, everyday use, maintenance and troubleshooting for the air purifier for rooms up to 398 sq. ft., with verified specifications.
- Room sizeUp to 398 sq. ft.
- Smoke CADR257 CFM
- Efficiency7.3 CFM/W
- Est. yearly cost$35.19
About the Honeywell HPA6000B
Honeywell model HPA6000B is an air purifier for rooms up to 398 sq. ft. that meets ENERGY STAR efficiency requirements.
Its clean air delivery rate (CADR) is 257 CFM for smoke, 262 CFM for dust, and 285 CFM for pollen, with a PM2.5 CADR of 259 CFM. In a 398 sq. ft. room with an 8 ft ceiling, the smoke CADR works out to about 4.8 air changes per hour.
Air passes through a HEPA filter and an activated-carbon filter.
Efficiency is rated at 7.3 CFM of PM2.5 clean air per watt (integrated energy factor). That beats 81% of the 85 Medium Room models in our database. The certification test recorded no ozone emissions.
Specifications
| Brand | Honeywell |
|---|---|
| Model number | HPA6000B |
| Size class | Medium Room |
| Recommended room size | 398 sq. ft. |
| Smoke CADR | 257 CFM |
| Dust CADR | 262 CFM |
| Pollen CADR | 285 CFM |
| PM2.5 CADR | 259 CFM |
| Integrated energy factor (PM2.5 CADR per watt) | 7.3 CFM/W |
| Smoke CADR per watt | 7.30 CFM/W |
| Annual energy use | 207 kWh/yr |
| Cleaning technology | Fan and Filter |
| Filter type(s) | HEPA, Activated Carbon |
| Ozone emissions | 0.00 ppb |
| Smart / connected features | No |
| ENERGY STAR Most Efficient | No |
Safety information
- Plug the purifier directly into a working household outlet. Do not run the cord under rugs or furniture, and do not use a damaged cord or plug.
- Unplug the unit before opening the filter door, changing filters or cleaning it.
- Do not operate the purifier without its filters installed, and use only filters intended for this model.
- Keep the air inlet and outlet clear; never insert objects into the grilles or let children play with the unit.
- Do not use the purifier near water, in a bathroom while showering, or where flammable vapors or aerosols are present.
- An air purifier does not remove carbon monoxide or radon and is not a substitute for ventilation. Keep CO alarms in the home.
Installation and first-time setup
- Remove packaging from the filters
Open the filter door and take every filter out of its plastic bag. Running the purifier with filters still wrapped blocks airflow and can overheat the motor.
- Reinstall filters in order
Fit the filters back in the order and orientation marked on their frames — this model has 2 filter stages: a HEPA filter and an activated-carbon filter. Most filters have an airflow arrow; it should point toward the fan.
- Choose a location
Place the purifier on a firm, level surface in the room where you spend the most time, with at least a foot or two of clearance from walls, curtains and furniture on the intake and outlet sides.
- Size the space
This model is rated for rooms up to 398 sq. ft. (37 m²) with standard 8 ft ceilings. For higher ceilings, open-plan areas or allergy and smoke concerns, treat a smaller area or add a second unit.
- Power on and reset indicators
Plug in, run the unit on high for a few minutes, and reset the filter-life indicator if the manual asks you to after installing new filters.
| Room area (8 ft ceiling) | Air changes at smoke CADR |
|---|---|
| 400 sq. ft. | 4.8 per hour |
| 300 sq. ft. | 6.4 per hour |
| 200 sq. ft. | 9.6 per hour |
Using your air purifier
Choosing a fan speed
Run the purifier continuously — particles are released all day, and a purifier only cleans the air that passes through it. Use high speed for 20–30 minutes after cooking, cleaning or when smoke is present, then drop to a lower, quieter speed for everyday use. The 257 CFM smoke CADR is measured at the highest speed; lower settings deliver proportionally less clean air.
Getting the best results
- Keep doors and windows in the room closed while the purifier runs so it is not trying to clean outdoor air.
- Remove the source where possible: vacuum with a HEPA vacuum, wash bedding weekly and keep pets out of the bedroom if they trigger allergies.
- Position the purifier near where you sit or sleep, with its outlet unobstructed, for the most noticeable benefit.
- Change filters on schedule; a loaded filter reduces CADR and can release odors.
Care and maintenance
| When | What to do |
|---|---|
| Every 2–4 weeks | Vacuum the pre-filter or outer mesh (if fitted) to remove hair and lint, and wipe the intake grille. |
| Every 3–6 months | Replace the activated-carbon filter, or sooner if odors return; carbon cannot be cleaned or regenerated by vacuuming. |
| Every 6–12 months | Replace the main HEPA filter when the indicator lights or as the manual specifies. Do not wash or vacuum the pleated media — it damages the fibers. |
| As needed | Wipe the cabinet with a dry or slightly damp cloth. Never spray cleaners into the grilles. |
Troubleshooting
Most air purifier issues relate to filters, placement or the filter-door safety switch. Work through these checks before contacting support. If the display shows a code, consult the code table in your manufacturer's manual.
| Problem | Possible cause | What to try |
|---|---|---|
| Unit will not turn on | Filter door not fully closed (safety switch); outlet not live; child lock on. | Close the filter door firmly; try another outlet; check the manual for unlocking the controls. |
| Weak airflow | Filter still in its bag or overloaded; intake blocked. | Remove packaging, replace or clean filters, and clear space around the intake. |
| Louder than usual | Filter loaded or misaligned; unit on an uneven surface; debris in the fan. | Reseat or replace the filter, move to a level surface, and unplug before checking the fan area. |
| Odor from the unit | Saturated carbon filter; new-filter smell; filter absorbing cooking or smoke odors. | Replace the carbon filter (or the main filter if odors persist); run on high in a ventilated room for a few hours if the filter is new. |
| Filter light stays on | Indicator not reset after replacing the filter. | Follow the manual's reset procedure, usually holding the filter button for several seconds. |
| Air still feels dusty | Room larger than the rating; doors or windows open; purifier on lowest speed. | Compare the room to the 398 sq. ft. rating, close the room, and run a higher speed. |
Energy use and running costs
The Honeywell HPA6000B is rated at 207 kWh per year, an ENERGY STAR estimate that assumes the purifier runs about 16 hours a day and sits in standby the rest of the time. At an average electricity price of $0.17 per kWh, that is about $35.19 per year, or $2.93 a month.
At the high-speed setting used for its CADR test it draws roughly 35 W, so running flat out around the clock would use about 308 kWh a year ($52.43). Everyday operation on a lower speed uses considerably less.
The integrated energy factor of 7.3 CFM/W means every watt delivers about 7.3 cubic feet per minute of PM2.5-free air, including standby losses. Higher numbers mean more clean air for the same electricity.
Replacement filters are usually a larger running cost than electricity, so factor their price and replacement interval into your budget.
Frequently asked questions
What size room is the Honeywell HPA6000B designed for?
It is rated for rooms up to 398 sq. ft. with 8 ft ceilings, which corresponds to about 4.8 air changes per hour at its 257 CFM smoke CADR. For allergies or smoke, use it in a smaller room or run it on high.
What is the CADR of the Honeywell HPA6000B?
Its clean air delivery rates are 257 CFM for smoke, 262 CFM for dust, and 285 CFM for pollen, plus a PM2.5 CADR of 259 CFM. Higher CADR means faster cleaning.
Does the Honeywell HPA6000B use a true HEPA filter?
Yes. The certification lists a HEPA filter plus an activated-carbon stage for odors. True HEPA media captures at least 99.97% of 0.3-micron particles.
Does the Honeywell HPA6000B produce ozone?
Its certification test recorded 0 ppb of ozone.
How much electricity does the Honeywell HPA6000B use?
It is rated at 207 kWh per year, about $35.19 at $0.17/kWh, assuming roughly 16 hours of operation a day.
Can I control the Honeywell HPA6000B from my phone?
No. The certified configuration has no app connectivity.
Sources and disclaimer
Specifications on this page come from the ENERGY STAR certified air purifiers dataset published by the U.S. Environmental Protection Agency (record certified March 23, 2025), retrieved October 7, 2026.
The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with Honeywell. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact Honeywell or an authorized service provider for warranty repairs and replacement parts.
Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.
Report a problem with this guide
Spotted a wrong value, a broken link or something unclear? Tell us and we will review it.