  • Blade span52 in.
  • Efficiency132 CFM/W
  • Power (high)31.2 W
  • Rated forIndoor use

About the WAC Lighting F-035L

The WAC Lighting F-035L is a 52 in. hugger ceiling fan with light kit certified under the ENERGY STAR program. It is sold as the Odyssey Flush 52. A 52 in. blade span is generally suited to rooms of roughly 225–400 sq. ft., such as a large bedroom or family room.

As a hugger (low-profile) model, it mounts close to the ceiling without a downrod, which suits rooms with ceilings under about 8 ft. The light kit produces 2,200 lumens from 25 W, with a 2700 K color temperature and a color rendering index (CRI) of 93.

Its rated airflow efficiency is 132 CFM per watt, and it draws 4.5 W on low and 31.2 W on high with 1.4 W of standby power. That efficiency is higher than 27% of the 167 Hugger models in our database.

Specifications

WAC Lighting F-035L specifications
BrandWAC Lighting
Model numberF-035L
Model name / seriesOdyssey Flush 52
Fan typeHugger
Blade span (diameter)52 in.
Indoor / outdoor ratingIndoor
Light kit includedYes
Airflow efficiency132.3 CFM/W
Power at low speed4.5 W
Power at high speed31.2 W
Standby power1.4 W
Smart / connected featuresNo
Light output2,200 lumens
Light power25.0 W
Color temperature2700 K
Color rendering index (CRI)93
Rated light-source life54,000 hours
Dimmable lightYes
Fan components warranty (as listed)3 years
ENERGY STAR Most EfficientNo

Safety information

  • Turn off power at the circuit breaker — not just the wall switch — before installing, wiring or servicing the fan, and confirm the power is off with a non-contact voltage tester.
  • Mount the fan only to an electrical box marked as acceptable for fan support (or to a fan-rated brace), secured directly to the building structure. Ordinary light-fixture boxes are not designed to carry a moving fan.
  • Keep the lowest point of the blades at least 7 ft above the floor and well clear of furniture, bunk beds, cabinets and doors.
  • If you are not comfortable with household wiring, have the fan installed by a licensed electrician in accordance with local codes.
  • Do not bend blade brackets or mix blades from different sets — this upsets the balance and can loosen hardware.
  • Allow the light kit to cool before touching it, and do not exceed the wattage or use bulbs other than those specified in the manual.

Installation and first-time setup

With a 52 in. (132 cm) blade span, center the fan in the room or over the main seating area and keep the blade tips at least 18 in. from walls and sloped ceilings. Hugger fans mount close to the ceiling, which is ideal for low ceilings but gives slightly less airflow than a downrod fan of the same size.

  1. Check the electrical box

    Confirm the ceiling box is metal or plastic marked for fan support and fastened to a joist or a fan-rated brace. Replace it if it is a standard light box.

  2. Assemble on the floor

    Unpack all parts, check them against the parts list, and pre-assemble the downrod or mounting bracket, canopy and motor housing as the manual describes. Leave the blades off until the motor is hung, if the manual allows.

  3. Hang the motor

    Attach the mounting plate to the box and lift the motor onto it, engaging the hanging tabs or screws before letting go.

  4. Make the wiring connections

    Connect the supply wires as the wiring diagram shows — typically black (hot) to black, white (neutral) to white, and the green or bare wire to ground — using properly sized wire connectors. Fans with light kits often have a separate (commonly blue) wire for the light; connect it as the diagram shows. If a receiver for a remote or wall control is supplied, install it in the canopy as shown.

  5. Attach blades and light

    Fasten each blade securely and tighten every screw evenly. Plug in or mount the light kit, then fit the glass or diffuser. Restore power and test every speed and the light.

  6. Balance the fan

    If the fan wobbles noticeably on high, check that all blade and bracket screws are tight, then use the balancing kit supplied with the fan to find and correct the light blade.

Using your ceiling fan

Summer and winter direction

In warm weather, run the fan counterclockwise (as seen from below) so the blades push air down and create a cooling breeze. In cold weather, switch to clockwise on low speed to gently draw air up and push warm air that collects at the ceiling down along the walls without creating a draft. Stop the fan completely before changing direction.

Saving energy with a ceiling fan

A ceiling fan cools people, not rooms — the moving air makes skin feel cooler through evaporation. If you use air conditioning, the breeze lets you raise the thermostat by about 4 °F without losing comfort, which cuts cooling costs far more than the fan itself costs to run. At high speed this fan draws about 31.2 W, a small fraction of what a central or room air conditioner uses. Turn the fan off when you leave the room.

Using the light

The light kit produces about 2,200 lumens from 25 W, roughly the output of one 100-watt incandescent bulb or more. The light is listed as dimmable; use the dimming function on the supplied control rather than adding a separate wall dimmer unless the manual approves one.

Care and maintenance

WhenWhat to do
Every monthDust the blades with a microfiber cloth or a pillowcase slipped over each blade so dust falls inside it. Heavy dust adds weight and can cause wobble.
Every 6 monthsWith power off, check that the canopy, downrod set screws, blade screws and light-kit fasteners are tight.
Twice a yearChange the rotation direction for the season.
As neededReplace remote-control batteries when the range drops. Wipe the motor housing with a dry or barely damp cloth — never spray liquid into the motor.
As neededClean the light glass or diffuser. The light source is rated for about 54,000 hours; if it fails, follow the manual for replacing the LED module or bulbs.

Troubleshooting

Most ceiling fan problems are caused by loose hardware, wiring connections or an incompatible control. Turn off power at the breaker before checking anything inside the canopy or housing.

ProblemPossible causeWhat to try
Fan will not startBreaker off; wall switch off; loose wire connection; remote not paired.Check the breaker and switch; with power off, recheck connections in the canopy; re-pair the remote following the manual.
Fan wobblesLoose blade or bracket screws; blades out of balance; mounting not secure.Tighten all screws, confirm the box is fan-rated and secure, then use the balancing kit.
Clicking noiseLoose blade screws, light glass or canopy; downrod not seated.Tighten fasteners and reseat the downrod ball in the bracket.
Humming noiseIncompatible wall control or dimmer; loose canopy.Use only the control supplied or approved for the fan; tighten the canopy.
Remote does not workWeak battery; receiver code mismatch; wall switch off.Replace the battery, re-pair the remote, and leave the wall switch on.
Little airflow feltFan turning in winter (clockwise) direction; blades too close to the ceiling; fan too small for the room.Switch to counterclockwise for summer and compare the room with the 52 in. blade span guidance.
Light flickers or will not turn onLoose light-kit connector; dimmer not compatible; failed LED module.With power off, reseat the connector; remove any non-approved dimmer; contact the manufacturer for a replacement module.

Energy use and running costs

Ceiling fan certification data lists power draw rather than an annual energy figure, so the table below estimates yearly use for the WAC Lighting F-035L at an average electricity price of $0.17 per kWh. Adjust the hours to match how you use the fan.

ScenarioPowerEnergy per yearCost per year
High speed, 8 h/day31.2 W91 kWh$15.49
Low speed, 8 h/day4.5 W13.1 kWh$2.23
Standby, 16 h/day1.4 W8.2 kWh$1.39
Light on, 3 h/day25 W27.4 kWh$4.65

Its airflow efficiency of 132 CFM/W is the ratio of air moved to power used under the DOE test procedure. A more efficient fan moves the same air for less electricity.

Frequently asked questions

What size room is the WAC Lighting F-035L suitable for?

With a 52 in. blade span, it is best suited to rooms of roughly 225–400 sq. ft., such as a large bedroom or family room. Very large or long rooms often work better with two fans.

How energy efficient is the WAC Lighting F-035L?

It is rated at 132 cubic feet per minute of airflow per watt. Higher CFM/W means more air moved for each watt of electricity.

How many watts does the WAC Lighting F-035L use?

About 4.5 W on low and about 31.2 W on high, plus 1.4 W in standby. Running on high for 8 hours a day costs about $15.49 a year at $0.17/kWh.

Can the WAC Lighting F-035L be installed outdoors?

No. It is listed for indoor use only. Choose a damp- or wet-rated fan for porches and patios.

Does the WAC Lighting F-035L have a light?

Yes. It includes a light kit rated at 2,200 lumens with a 2700 K color temperature, and the light is dimmable.

Is the WAC Lighting F-035L a smart fan?

No. The certified configuration has no app or network connectivity; it is operated with its supplied control.

What warranty does the WAC Lighting F-035L have?

The ENERGY STAR listing reports a 3-year warranty on fan components. Confirm the full terms, including motor and light-kit coverage, with the manufacturer.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified ceiling fans dataset published by the U.S. Environmental Protection Agency (record certified November 19, 2020), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with WAC Lighting. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact WAC Lighting or an authorized service provider for warranty repairs and replacement parts.