Commercial Coffee BrewersLarge Batch

BUNN ITCB-DV HV Commercial Coffee Brewer Manual

Setup, everyday use, maintenance and troubleshooting for the large-batch coffee brewer, with verified specifications.

  • Output15 gal/h
  • Tank2.88 gal
  • Preheat36.5 min
  • Standby draw78 W

About the BUNN ITCB-DV HV

BUNN model ITCB-DV HV is a large-batch coffee brewer that meets ENERGY STAR requirements for food-service equipment. ENERGY STAR classifies it as a large-batch, Type II brewer.

It combines a 2.88 gal (369 fl oz) hot-water tank and a rated production capacity of 15 gallons of coffee per hour — roughly 240 cups of 8 oz each. In ready-to-brew mode the tank averaged 200 °F during testing, in line with the 195–205 °F (90–96 °C) brewing range recommended by the Specialty Coffee Association; water cools slightly between the tank and the sprayhead.

Its normalized ready-to-brew idle rate is 27.1 W per gallon of tank capacity, which works out to about 78 W to keep the full tank hot between batches. That is lower than 56% of the 19 commercial coffee brewer brewers in our database.

It also has an energy-save mode that cuts the idle rate to 5.02 W/gal (about 14.5 W) during long idle periods such as overnight.

Specifications

BUNN ITCB-DV HV specifications
BrandBUNN
Model numberITCB-DV HV
Batch size classLarge Batch
ENERGY STAR product typeLarge Batch Type II
Hot-water tank capacity2.88 gal
Production capacity15.0 gal/h
Average tank temperature (ready to brew)200 °F
Maximum serving temperature187 °F
Preheat time36.5 min
Preheat energy950 Wh
Normalized ready-to-brew idle rate27.13 W/gal
Ready-to-brew idle draw (calculated)78 W
Energy-save modeYes
Normalized energy-save idle rate5.02 W/gal
Normalized heavy-use brew energy rate260.28 W/gal

Safety information

  • Water in the tank is held near 200 °F (93 °C) and can scald instantly. Keep hands away from the sprayhead, and never remove the brew funnel while brewing or while coffee is still dripping.
  • Carry full servers and airpots level with both hands, and make sure lids are seated before moving them.
  • Do not switch on the tank heater until the tank has filled with water. Running the heater dry can destroy the element and damage the tank.
  • Have the brewer connected by qualified tradespeople: electrical work to the voltage, phase and amperage on the data plate, and plumbing to a potable cold-water line with a shut-off valve and the backflow prevention your plumbing code requires.
  • Disconnect power before removing panels or cleaning beneath the sprayhead area. Never immerse the brewer or spray it with water.
  • Wear gloves and eye protection when deliming or using brewer cleaners, and rinse thoroughly before brewing coffee for service.

Installation and first-time setup

  1. Choose the location

    Set the brewer on a level counter strong enough for its weight with a full tank and full servers. Leave room above for removing the funnel and servicing the sprayhead, and keep it within reach of the water line and receptacle or disconnect.

  2. Install water treatment

    Fit the water filter or treatment system recommended for your local water. Filtration improves coffee flavor and reduces scale in the tank, which is the leading cause of brewer service calls.

  3. Connect the water supply

    Flush the supply line before connecting it to remove debris, then connect to a cold-water line with a shut-off valve and confirm the pressure is within the range in the installation manual. Check every fitting for leaks.

  4. Connect power

    Confirm that the supply voltage and configuration match the data plate. Hard-wired models must be connected by a licensed electrician.

  5. Fill the tank

    With the tank heater switched off, fill the tank as the manual describes — usually until water flows from the sprayhead or the fill valve shuts off.

  6. Heat up

    Switch on the tank heater and wait for the ready indicator. A full preheat from cold took about 36.5 minutes in testing. Expect some water to drip from the sprayhead as the water expands while heating.

  7. Calibrate batch volumes

    Brew hot water (no coffee) into a measuring container for each batch setting and adjust the volumes per the manual until they match your servers.

  8. Adjust for altitude

    At high elevations water boils at a lower temperature. If the tank vents steam or boils, lower the temperature setting as the manual directs.

Using your coffee brewer

Brewing a batch

  1. Place a clean paper or permanent filter in the brew funnel.
  2. Add freshly ground coffee and shake the funnel gently to level the bed so water extracts it evenly.
  3. Slide the funnel fully into its rails and center an empty, preheated server beneath it.
  4. Select the batch size, then start the brew cycle.
  5. Wait until dripping stops before removing the funnel, then discard the grounds and filter.

Follow your roaster's dose and grind recommendations. As a reference point, the Specialty Coffee Association's Golden Cup guideline is about 55 g of coffee per liter of water (roughly 7 oz per gallon). Keep the dose and grind consistent from batch to batch.

Holding brewed coffee

Serve from clean, preheated servers and label each with its brew time. Brewed coffee loses aroma and turns bitter over time, so set a discard time that fits your quality standard and never reheat or re-brew through old coffee. The maximum serving temperature recorded during testing was 187 °F. Pour carefully: coffee served this hot can cause burns.

Using energy-save mode

Energy-save mode reduces tank heating during long idle periods, cutting the idle rate from 27.1 W/gal to 5.02 W/gal. Set it to engage after closing time or a period without brewing, and allow time for the tank to recover before the first batch of the day. Your manual describes how to set the delay and wake-up behavior.

Care and maintenance

WhenWhat to do
After each batchDiscard grounds and filter; rinse the funnel.
DailyWash the brew funnel and servers with a coffee-equipment cleaner to remove oils, rinse well and air-dry. Wipe the sprayhead area, drip tray and exterior.
WeeklyRemove the sprayhead, clear any blocked holes and wash it; clean the sprayhead fitting. A partly blocked sprayhead channels water and gives weak, uneven coffee.
As scale requiresDelime the tank and sprayhead tube following the manufacturer's procedure — more often in hard-water areas. Scale insulates the heating element and slows recovery.
Per filter ratingReplace the water-filter cartridge at the gallon or time interval specified by the filter manufacturer.
AnnuallyHave a qualified technician check the tank heater, thermostat, high-limit, inlet valve and wiring, and inspect the tank for scale.

Troubleshooting

Most brewing problems come down to grind, dose, water or scale. Digital controls may display brand-specific messages — consult the code table in your manufacturer's manual.

ProblemPossible causeWhat to try
Brewer will not start a cycleNo power; water supply off; tank not yet at temperature; funnel not fully seated.Check power and the water valve; wait for the ready indicator; reseat the funnel.
Weak coffeeGrind too coarse; dose too low; batch volume set too high; blocked sprayhead holes.Adjust grind and dose; recalibrate batch volume; clean the sprayhead.
Bitter or harsh coffeeGrind too fine; coffee held too long; servers not cleaned.Coarsen the grind; shorten holding time; clean servers daily.
Funnel overflowsGrind too fine; too much coffee; two filters stacked; wrong filter size; sprayhead missing.Correct the grind, dose and filter; make sure the sprayhead is installed.
Coffee not hot enoughTank temperature set low; high-limit tripped; servers not preheated; held too long.Raise the setting within the manual's range; preheat servers. If the tank stays cold, call a technician.
Batch volume short or inconsistentLow water pressure; clogged inlet strainer or flow regulator; scale.Check supply pressure and the filter cartridge; delime; have the inlet strainer cleaned.
Water keeps dripping from the sprayheadNormal expansion while heating; inlet valve not sealing.A few drips after heating are normal. Continuous dripping means the inlet valve needs service.
Steam or water from the tank ventTemperature set too high for the altitude; heavy scale.Lower the temperature setting; delime the tank.

Energy use and running costs

Keeping the tank hot draws about 78 W (27.1 W/gal × 2.88 gal). Left in ready-to-brew mode around the clock, that standby heat alone comes to about 683 kWh a year — $116 at $0.17 per kWh, or $0.32 a day.

With energy-save mode active for the 12 closed hours of each day, standby energy drops to about 405 kWh a year ($68.88), saving roughly $47.28 a year.

A full preheat from cold used 950 Wh (0.95 kWh, about $0.16) and took 36.5 minutes in testing.

During heavy, continuous brewing the normalized brew energy rate is 260 W/gal. Brewing energy depends mainly on how much coffee you make; standby losses are the part good habits can control.

These estimates cover standby heat only, 365 days a year, with a 12-hour service day and 12 closed hours; they exclude the energy used to brew. Actual costs depend on your hours, volume and utility rates.

Frequently asked questions

How much coffee can the BUNN ITCB-DV HV brew per hour?

It is rated at 15 gallons per hour — about 1,917 fl oz, or roughly 240 cups of 8 oz each, drawing on a 2.88 gal hot-water tank.

How long does the BUNN ITCB-DV HV take to heat up?

A full preheat from cold took 36.5 minutes in ENERGY STAR testing and used about 0.95 kWh. Switch it on at least that long before the first brew of the day.

Does the BUNN ITCB-DV HV have an energy-save mode?

Yes. In energy-save mode its idle rate drops to 5.02 W/gal, compared with 27.1 W/gal when ready to brew.

How much electricity does the BUNN ITCB-DV HV use on standby?

About 78 W to keep its tank hot, based on the normalized idle rate of 27.1 W/gal. Left ready around the clock, that is roughly $116 a year at $0.17/kWh.

What water temperature does the BUNN ITCB-DV HV brew at?

Its tank averaged 200 °F in ready-to-brew mode during testing. Ideal brewing water is 195–205 °F at the coffee; lower the setting at high altitude if the tank begins to boil.

How often should I delime my BUNN brewer?

It depends on water hardness and volume. With good filtration, many operators delime every few months; in hard-water areas it may be monthly. Slow recovery, short batches or visible scale on the sprayhead are signs it is due.

Is the BUNN ITCB-DV HV ENERGY STAR certified?

Yes. It appears on the ENERGY STAR list of certified commercial coffee brewers, with a certification date of August 18, 2021.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified commercial coffee brewers dataset published by the U.S. Environmental Protection Agency (record certified August 18, 2021), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with BUNN. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact BUNN or an authorized service provider for warranty repairs and replacement parts.

Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.