Commercial Steam CookersGas Boiler-Based

Market Forge ETP-10G Commercial Steam Cooker Manual

Setup, everyday use, maintenance and troubleshooting for the 10-pan gas boiler-based steamer, with verified specifications.

  • Pan capacity10 full-size pans
  • Steam sourceBoiler-based, gas
  • Cooking efficiency40%
  • Idle rate5,766 Btu/h

About the Market Forge ETP-10G

The Market Forge ETP-10G is a 10-pan gas boiler-based steamer certified under the ENERGY STAR commercial steam cooker program. It holds up to 10 standard 12 × 20 × 2.5 in. hotel pans in a pressureless (atmospheric) compartment, so the door can be opened mid-cycle without waiting for pressure to bleed off.

This is a boiler-based steamer: a separate steam generator produces steam and feeds it into the cooking compartment. Generator-type steamers recover quickly under heavy, continuous loads, but they use more water than boilerless designs and need daily blowdown and regular deliming to keep the generator free of scale. Rated water consumption is 8 gal/h.

In the ASTM heavy-load test it reached a cooking-energy efficiency of 40%, meaning 40% of the gas energy consumed during cooking ended up in the food.

When it is hot and ready but not cooking, it draws 5,766 Btu/h — about 577 Btu/h per pan of capacity.

Specifications

Market Forge ETP-10G specifications
BrandMarket Forge
Model numberETP-10G
Model name / seriesEco-Tech Plus
Steamer typeGas Boiler-Based
Steam generationBoiler-Based
Compartment designPressureless
Pan capacity10 pans (12 × 20 × 2.5 in.)
Cooking-energy efficiency40%
Idle energy rate5,766 Btu/h
Idle rate per pan (calculated)577 Btu/h
Water consumption8.00 gal/h

Safety information

  • Steam causes severe burns instantly. Stand to the side of the door when opening it, open it a little first so steam can escape, and keep your face and arms out of the steam path.
  • Pans, racks and condensate are at or near 212 °F (100 °C). Use dry oven mitts — wet mitts conduct heat — and slide pans out level so hot liquid does not spill.
  • Place pans that contain liquid on lower shelves, below eye level, to reduce the risk of spills onto your face and hands.
  • Never defeat or bypass the door switch or interlock.
  • Do not install the steamer next to a fryer without proper separation; water or condensate reaching hot oil can cause violent spattering.
  • Deliming chemicals are corrosive. Wear gloves and eye protection, use only the delimer the manufacturer approves, never mix it with chlorine bleach, and rinse the compartment thoroughly before cooking.
  • If you smell gas, shut off the appliance supply valve, do not operate electrical switches or light any flame, ventilate the area and call your gas supplier from outside the building.
  • Keep the flue outlet clear and never place pans or towels over it. Gas connections and adjustments must be made by a licensed technician; leak-test with soap solution, never a flame.
  • Do not hose down or pressure-wash the exterior or controls. Water entering electrical compartments creates a shock and fire hazard.

Installation and first-time setup

  1. Choose the location

    Install on a level, non-combustible surface or the manufacturer's stand with the clearances listed in the installation manual. Check local code: many jurisdictions require steamers under an exhaust hood, and gas units must vent flue products as the manual specifies.

  2. Level the unit

    Level the steamer side to side and front to back. A level cabinet keeps condensate draining properly and helps the door seal evenly.

  3. Connect treated and untreated water

    Many boiler-based steamers have two inlets: treated water for the steam generator and untreated cold water for the drain condenser that cools discharge water. Connect each as the manual directs, with shut-off valves, and install the water treatment system the manufacturer specifies.

  4. Test the water

    Have your water tested for hardness, chlorides and pH and compare the results with the limits in the installation manual. Hard water scales heating surfaces; high chlorides pit stainless steel. Manufacturers may exclude scale or corrosion damage from warranty coverage when water requirements are not met.

  5. Connect the drain

    Run the drain at full size to an open floor sink with an air gap — do not connect it directly to the sewer. Keep drain lines short and free of dips where water can collect.

  6. Connect gas

    Connect the gas supply with a correctly sized connector and accessible shut-off valve. Leak-test every joint and have the technician verify the manifold pressure on the data plate.

  7. First run

    Remove all packaging, wash pans and racks, then run the steamer empty through a full heat-up and cycle. Check for leaks at the door, drain and water connections and confirm the ready indicator comes on.

Using your steamer

Choosing and loading pans

The rated capacity of 10 pans assumes standard 2.5 in. deep full-size pans; deeper pans take more than one shelf position and lengthen cook times. Spread food in an even, shallow layer and leave the shelf positions between deep pans open so steam can circulate.

Pan typeUse it forWhy
PerforatedVegetables, potatoes, seafood, dumplingsCondensate drains away, so food steams instead of boiling in collected water.
SolidRice, grains, pasta, eggs, foods in sauce or liquidHolds the cooking liquid and catches drips.
Solid pan under perforatedItems that release juices, such as shellfishCatches drippings that would otherwise flavor food below or run to the drain.

Cooking cycles

Preheat until the ready indicator shows, load the pans, close the door and start timing. Every door opening releases steam and adds recovery time, so check doneness at the end of the cycle rather than repeatedly. Start with the manufacturer's time chart and record your own times for each product and pan depth.

Food safety

  • Hold hot foods at 135 °F (57 °C) or above, verified with a calibrated probe thermometer.
  • Cool cooked foods from 135 °F to 70 °F (21 °C) within 2 hours and to 41 °F (5 °C) or below within a further 4 hours (FDA Food Code).
  • Reheat previously cooked and cooled food to 165 °F (74 °C) within 2 hours before hot holding.
  • Do not leave cooked rice or grains at room temperature; spores of Bacillus cereus survive cooking and multiply between 41 °F and 135 °F.
  • Use clean, sanitized pans and racks, and keep raw seafood or meat on lower shelves when steaming mixed loads.

Steam generator blowdown

Minerals concentrate in the generator as water turns to steam. Blow down (drain) the generator at the end of each day as the manual describes — or confirm that the automatic blowdown cycle runs, if your model has one — to flush sediment and slow scale formation.

Saving energy

Switch the steamer off or to standby between meal periods and avoid preheating long before the first load. Each hour it sits ready without food costs about $0.09 at its rated idle input of 5,766 Btu/h. Batch-cook to order where the menu allows instead of holding steamed vegetables for long periods.

Care and maintenance

WhenWhat to do
After each service periodRemove pans and racks, wash, rinse and sanitize them. Wipe the compartment and clear the drain screen of food debris.
End of each dayBlow down the steam generator and clean the compartment with a non-abrasive pad and mild detergent. Rinse well.
End of each dayWipe the door gasket and leave the door slightly open overnight so the compartment dries and the gasket does not take a set.
WeeklyInspect the drain and condensate path for buildup, and check the door gasket for cracks or tears.
As scale requiresDelime the steam generator with the approved delimer — often weekly in very hard water and monthly or less with good water treatment. If your model has a delime indicator, follow it.
Per filter ratingReplace water-filter or treatment cartridges at the gallon or time interval the manufacturer specifies.
AnnuallyHave a qualified technician inspect burners, ignition, flue and gas connections, and check water-level controls and safety devices.

Troubleshooting

Most steamer problems trace back to water: supply, level, drainage or scale. Work through these checks before calling for service.

ProblemPossible causeWhat to try
No steam or unit will not heatGas valve closed; water supply off or reservoir empty; door not fully closed; ignition fault.Check the supply valve, water and door; reset a breaker once. If it does not heat, call a technician.
Cook times getting longerScale on heating surfaces; pans overloaded or too deep; door gasket leaking.Delime; use shallower layers and 2.5 in. pans; inspect and clean or replace the gasket.
Water leaking from the doorWorn or dirty gasket; unit not level; door latch out of adjustment.Clean or replace the gasket; re-level the unit; have the latch adjusted.
Steam escaping from the drain or ventCondenser (drain-cooling) water off or restricted; drain blocked.Confirm the untreated water supply to the condenser is on; clear the drain.
White deposits in the compartmentHard water; deliming overdue; treatment cartridge exhausted.Delime now; replace the cartridge; review your water treatment.
Food soggy or waterloggedVegetables cooked in solid pans; overcooking; condensate dripping from pans above.Use perforated pans; shorten the time; place a solid pan under dripping items.
Low-water, delime or other fault indicatorScaled water-level probes; low water pressure; brand-specific fault.Clean the probes, check supply pressure, and consult the code table in your manufacturer's manual.
Odors from the compartmentFood debris in the drain; door closed overnight while wet.Clean the drain screen and compartment; leave the door ajar to dry.

Energy use and running costs

At its rated idle input of 5,766 Btu/h, the Market Forge ETP-10G costs about $0.09 for every hour it sits ready without food, at $1.50 per therm. If it idles 6 hours a day, 312 days a year, that comes to roughly 108 therms — $162 a year before any cooking energy.

While cooking, 40% of the energy consumed reaches the food. For every 100 Btu of heat that actually cooks product, the steamer draws about 250 Btu from the gas line.

Rated water consumption is 8 gal/h. Running at that rate for a 12-hour day, 312 days a year, would use about 29,952 gallons — roughly $449 a year in water and sewer charges at $0.015 per gallon.

Real costs depend on how long the steamer is left on, load size, door openings and local utility rates.

Frequently asked questions

How many pans does the Market Forge ETP-10G hold?

It is rated for 10 standard full-size hotel pans (12 × 20 × 2.5 in.). Deeper pans reduce the number that fit, because each one takes more than one shelf position.

Is the Market Forge ETP-10G boilerless?

No. It uses a separate steam generator (boiler) to make steam, which needs daily blowdown and regular deliming to stay free of scale.

How much water does the Market Forge ETP-10G use?

Its rated water consumption is 8 gallons per hour, or about 96 gallons over a 12-hour day at that rate.

How energy efficient is the Market Forge ETP-10G?

It tested at 40% cooking-energy efficiency under the ASTM heavy-load test. Gas steamers lose some heat up the flue, so compare it with other gas models.

How much energy does the Market Forge ETP-10G use when idle?

Its idle energy rate is 5,766 Btu/h, which costs about $0.09 per hour or roughly $162 a year at 6 idle hours a day, 312 days a year.

How often should I delime my Market Forge steamer?

It depends on your water. In very hard water, deliming may be needed weekly; with proper treatment, monthly or less. Delime whenever you see white scale on the generator or probes, and follow any delime indicator on the unit.

Is the Market Forge ETP-10G ENERGY STAR certified?

Yes. It appears on the ENERGY STAR list of certified commercial steam cookers, with a certification date of April 6, 2011.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified commercial steam cookers dataset published by the U.S. Environmental Protection Agency (record certified April 6, 2011), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with Market Forge. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact Market Forge or an authorized service provider for warranty repairs and replacement parts.

Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.