LED DownlightsRecessed

ConTech Lighting R[N]2ANC1MVD UMOD[N]40KF LED Downlight Manual

Setup, everyday use, maintenance and troubleshooting for the 2 in. recessed LED downlight, with verified specifications.

  • Light output1,133 lumens
  • Power9.64 W
  • Efficacy118 lm/W
  • Color temp.2700–4000K (selectable)

About the ConTech Lighting R[N]2ANC1MVD UMOD[N]40KF

This guide covers the ConTech Lighting R[N]2ANC1MVD UMOD[N]40KF, a 2 in. recessed LED downlight listed as ENERGY STAR certified. It produces 1,133 lumens from 9.64 W of input power, an efficacy of 118 lumens per watt. That efficacy is better than 98% of the 3,089 Recessed models in our database.

Light quality: the fixture offers selectable color temperatures of 2700K, 3000K, 3500K, or 4000K and a color rendering index of 83.

Notable features include continuous dimming (0–10 V supported). The rated light-source life is 77,000 hours.

Specifications

ConTech Lighting R[N]2ANC1MVD UMOD[N]40KF specifications
BrandConTech Lighting
Model numberR[N]2ANC1MVD UMOD[N]40KF
Fixture typeRecessed
Nominal size / aperture2 in.
Light output1,133 lumens
Input power9.6 W
Efficacy117.5 lm/W
Color temperature(s)2700K, 3000K, 3500K, 4000K
Color rendering index (CRI)83
Rated light-source life77,000 hours
Power factor0.99
Continuously dimmableYes
Dimming control0–10 V
Indoor / outdoor useIndoor/Outdoor
Tunable / selectable whiteNo
Full-color tunableNo
Selectable light outputNo
Occupancy sensorNo
Connected (smart) capableNo

Safety information

  • Turn off power at the circuit breaker — not just the wall switch — before installing, removing or servicing the fixture, and confirm the circuit is dead with a non-contact voltage tester.
  • Installation must comply with the National Electrical Code (NEC) or Canadian Electrical Code (CEC) and local codes. Many jurisdictions require a licensed electrician and a permit for new fixture locations or new wiring; if you are not comfortable with household wiring, hire one.
  • Use only the junction box, housing, or mounting hardware specified in the installation instructions, and do not exceed the box-fill limits of the junction box.
  • Install the fixture only on a circuit whose voltage matches the label, and never modify the LED driver or module.
  • Connect dimmable fixtures only to dimmers the manufacturer lists as compatible, and keep the total connected LED load within the dimmer's LED rating (often much lower than its incandescent rating).

Installation and first-time setup

Recessed downlights mount above the ceiling, either in a new-construction housing fixed to joists before the drywall goes up or in a remodel housing that clips into a cutout in an existing ceiling. This model is a 2 in. fixture; use the cutout template from the manufacturer — never estimate the hole size.

  1. Plan the layout

    Check for joists, ducts and pipes before cutting. As a starting point for general lighting, space fixtures about as far apart as the ceiling is high, and keep them about half that distance from walls; use closer spacing or more lumens for task areas.

  2. Turn off power

    Switch off the breaker feeding the circuit and verify it is dead.

  3. Cut the opening

    Trace the template and cut the opening with a drywall saw or hole saw. Keep the cut clean so the trim covers it fully.

  4. Wire the junction box

    Feed the supply cable into the fixture's junction box through a cable clamp. Connect line to line, neutral to neutral and ground to ground with listed connectors, and close the box cover.

  5. Set options

    Set the color-temperature selector before the fixture goes into the ceiling.

  6. Install the fixture

    Push the housing or canless module into the opening until the mounting clips or springs grip the drywall and the trim sits flush.

  7. Restore power and test

    Turn on the breaker and check operation through the full dimming range.

Using your downlight

Dimming

The fixture dims continuously. In addition to phase-cut (wall-box) dimming where supported, the certification data lists 0–10 V dimming. Check the manufacturer's compatibility list: most LED drivers work best with trailing-edge (ELV) or LED-rated dimmers, and some dimmers have a low-end trim adjustment that stops flicker at the bottom of the range.

0–10 V dimming uses a separate pair of low-voltage control wires (usually purple and gray, or purple and pink) run to a 0–10 V dimmer or lighting controller. Keep the control wiring separated from line-voltage conductors as the instructions and code require.

Choosing a color temperature

This fixture can be set to 2700K, 3000K, 3500K, or 4000K. Set every fixture in a room to the same setting — mismatched color temperatures are very noticeable.

SettingAppearanceTypical use
2700KWarm white, similar to incandescentLiving rooms, bedrooms, dining areas
3000KSoft warm white, similar to halogenKitchens, living spaces, hospitality
3500KNeutral warmKitchens, retail, offices
4000KNeutral / cool whiteOffices, laundry rooms, garages

Light output and placement

At 1,133 lumens, this fixture is in the typical range for general lighting in kitchens, living areas and offices with 8–9 ft ceilings. LED fixtures reach full brightness instantly and are not shortened by frequent switching.

Care and maintenance

WhenWhat to do
Every 3–6 monthsDust the trim and lens with a soft, dry microfiber cloth with the light off and cool. Do not spray cleaner directly onto the fixture.
Every yearCheck that the trim still sits flush and the springs or clips hold it firmly. A sagging trim can leave a gap that lets attic air leak.
When cleaning greasy kitchensWipe the lens with a cloth dampened in mild soapy water, then dry it. Avoid solvents and abrasive pads, which can cloud the lens.

The integrated LEDs are not user-replaceable bulbs. The rated light-source life of 77,000 hours works out to roughly 70 years at 3 hours a day, or about 18 years at 12 hours a day. Over time the LEDs gradually dim rather than burning out; when output becomes too low, or if the driver fails, replace the fixture or LED module as the manufacturer directs.

Troubleshooting

Most downlight problems trace back to dimmer compatibility or wiring connections. Always turn off the breaker before opening the fixture or the junction box.

ProblemPossible causeWhat to try
Light does not turn onBreaker off or tripped; loose wire connection; switch or dimmer failure.Check the breaker; with power off, confirm connections in the junction box are tight; test with a standard switch.
Flickers or buzzes when dimmedDimmer not compatible with the LED driver; dimmer low-end trim set too low; too many or too few fixtures on the dimmer.Use a dimmer on the manufacturer's compatibility list; adjust the dimmer's low-end trim; keep the load within the dimmer's LED rating.
Faint glow when switched offIlluminated or smart switch leaking a small current; shared neutral wiring issue.Try a standard switch; use a smart switch that has a neutral connection; have an electrician check the wiring.
Does not dim smoothly or turns off at low settingsDimmer range not matched to the driver.Raise the dimmer's minimum setting; consult the dimmer and fixture compatibility notes.
Color looks different from the other fixturesColor-temperature selector set differently from neighboring fixtures.Turn off power, check the selector setting and match it to the other fixtures.
Trim falls or hangs below the ceilingSprings or clips not engaged; opening cut too large.Reseat the springs in the receivers; use a trim with a wider flange or repair the drywall.
Turns off by itself after running a whileDriver overheating, often from insulation packed around a fixture or a loose connection.Turn off power and check the installation. Do not cover Non-IC fixtures with insulation; call an electrician if the problem continues.

Energy use and running costs

The ConTech Lighting R[N]2ANC1MVD UMOD[N]40KF draws 9.64 W. Used 3 hours a day — a typical home assumption — it consumes about 10.6 kWh a year, roughly $1.79 per year at an electricity price of $0.17 per kWh. In a commercial space lit 12 hours a day, the same fixture uses about 42 kWh, or $7.18 a year.

Efficacy — lumens of light per watt of electricity — is the best single measure of a fixture's efficiency. This model delivers 118 lm/W. That figure is better than 98% of the 3,089 Recessed models in our database.

Per fixture, at $0.17/kWh
Daily useEnergy per yearCost per year
1 hour3.5 kWh$0.60
3 hours10.6 kWh$1.79
6 hours21.1 kWh$3.59
12 hours42.2 kWh$7.18

The listed power factor is 0.99, high enough that the fixture draws current efficiently from the supply — useful in commercial buildings with many fixtures on one circuit.

Dimming reduces power roughly in proportion to light output.

Frequently asked questions

How bright is the ConTech Lighting R[N]2ANC1MVD UMOD[N]40KF?

It is rated at 1,133 lumens while drawing 9.64 W, for an efficacy of 118 lumens per watt.

Is the ConTech Lighting R[N]2ANC1MVD UMOD[N]40KF dimmable?

Yes. It is continuously dimmable, and the certification data also lists 0–10 V dimming. Use a dimmer the manufacturer lists as compatible for flicker-free operation.

What color temperature is the ConTech Lighting R[N]2ANC1MVD UMOD[N]40KF?

It is selectable between 2700K, 3000K, 3500K, and 4000K. Set the selector before installation.

What size is the ConTech Lighting R[N]2ANC1MVD UMOD[N]40KF?

Its nominal size is 2 in. Confirm the exact cutout or housing dimensions in the manufacturer's installation sheet before purchasing.

How much does it cost to run the ConTech Lighting R[N]2ANC1MVD UMOD[N]40KF?

At 3 hours a day and $0.17/kWh, it costs about $1.79 a year to operate.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified led downlights dataset published by the U.S. Environmental Protection Agency (record certified December 31, 2024), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with ConTech Lighting. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact ConTech Lighting or an authorized service provider for warranty repairs and replacement parts.

Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.