LED DownlightsRecessed

Leadvision L111-08R04X LED Downlight Manual

Setup, everyday use, maintenance and troubleshooting for the 4 in. recessed LED downlight, with verified specifications.

  • Light output700 lumens
  • Power8 W
  • Efficacy87.5 lm/W
  • Color temp.2700–5000K (selectable)

About the Leadvision L111-08R04X

This guide covers the Leadvision L111-08R04X, a 4 in. recessed LED downlight listed as ENERGY STAR certified. It produces 700 lumens from 8 W of input power, an efficacy of 87.5 lumens per watt. That efficacy is better than 59% of the 3,089 Recessed models in our database.

Light quality: the fixture offers selectable color temperatures of 2700K, 3000K, 3500K, 4000K, or 5000K and a color rendering index of 95, which renders skin tones, wood and fabrics accurately.

Notable features include continuous dimming, a wet-location rating, and an IC rating for direct contact with ceiling insulation. The rated light-source life is 54,000 hours.

Specifications

Leadvision L111-08R04X specifications
BrandLeadvision
Model numberL111-08R04X
Model name / series4-in LED Retro-Fit Recessed Light
Fixture typeRecessed
Nominal size / aperture4 in.
Light output700 lumens
Input power8.0 W
Efficacy87.5 lm/W
Color temperature(s)2700K, 3000K, 3500K, 4000K, 5000K
Color rendering index (CRI)95
Rated light-source life54,000 hours
Power factor0.86
Continuously dimmableYes
Location ratingWet location
Indoor / outdoor useIndoor
Insulation contact ratingIC
Airtight ratedNo
Electrical connectionE26 screw-in adapter
Tunable / selectable whiteYes
Full-color tunableNo
Selectable light outputNo
Occupancy sensorNo
Connected (smart) capableNo

Safety information

  • Turn off power at the circuit breaker — not just the wall switch — before installing, removing or servicing the fixture, and confirm the circuit is dead with a non-contact voltage tester.
  • Installation must comply with the National Electrical Code (NEC) or Canadian Electrical Code (CEC) and local codes. Many jurisdictions require a licensed electrician and a permit for new fixture locations or new wiring; if you are not comfortable with household wiring, hire one.
  • Use only the junction box, housing, or mounting hardware specified in the installation instructions, and do not exceed the box-fill limits of the junction box.
  • Install the fixture only on a circuit whose voltage matches the label, and never modify the LED driver or module.
  • Connect dimmable fixtures only to dimmers the manufacturer lists as compatible, and keep the total connected LED load within the dimmer's LED rating (often much lower than its incandescent rating).

Installation and first-time setup

Recessed downlights mount above the ceiling, either in a new-construction housing fixed to joists before the drywall goes up or in a remodel housing that clips into a cutout in an existing ceiling. This model is a 4 in. fixture; use the cutout template from the manufacturer — never estimate the hole size.

  1. Plan the layout

    Check for joists, ducts and pipes before cutting. As a starting point for general lighting, space fixtures about as far apart as the ceiling is high, and keep them about half that distance from walls; use closer spacing or more lumens for task areas.

  2. Turn off power

    Switch off the breaker feeding the circuit and verify it is dead.

  3. Cut the opening

    Trace the template and cut the opening with a drywall saw or hole saw. Keep the cut clean so the trim covers it fully.

  4. Wire the junction box

    Feed the supply cable into the fixture's junction box through a cable clamp. Connect line to line, neutral to neutral and ground to ground with listed connectors, and close the box cover.

  5. Set options

    Set the color-temperature selector before the fixture goes into the ceiling.

  6. Install the fixture

    Push the housing or canless module into the opening until the mounting clips or springs grip the drywall and the trim sits flush.

  7. Restore power and test

    Turn on the breaker and check operation through the full dimming range.

Because this fixture is wet-location rated, it is suitable for locations exposed to water, such as covered porches, eaves and shower areas where the manual permits. Code requires fixtures within 3 ft horizontally and 8 ft vertically of a tub rim or shower threshold to be rated at least for damp locations — wet-location rated where subject to shower spray — and a GFCI-protected circuit is often required in these areas.

Using your downlight

Dimming

The fixture dims continuously. Check the manufacturer's compatibility list: most LED drivers work best with trailing-edge (ELV) or LED-rated dimmers, and some dimmers have a low-end trim adjustment that stops flicker at the bottom of the range.

Choosing a color temperature

This fixture can be set to 2700K, 3000K, 3500K, 4000K, or 5000K. Set every fixture in a room to the same setting — mismatched color temperatures are very noticeable.

SettingAppearanceTypical use
2700KWarm white, similar to incandescentLiving rooms, bedrooms, dining areas
3000KSoft warm white, similar to halogenKitchens, living spaces, hospitality
3500KNeutral warmKitchens, retail, offices
4000KNeutral / cool whiteOffices, laundry rooms, garages
5000KCool white, daylight-likeWorkshops, garages, task areas

Light output and placement

At 700 lumens, this fixture is in the typical range for general lighting in kitchens, living areas and offices with 8–9 ft ceilings. LED fixtures reach full brightness instantly and are not shortened by frequent switching.

Care and maintenance

WhenWhat to do
Every 3–6 monthsDust the trim and lens with a soft, dry microfiber cloth with the light off and cool. Do not spray cleaner directly onto the fixture.
Every yearCheck that the trim still sits flush and the springs or clips hold it firmly. A sagging trim can leave a gap that lets attic air leak.
When cleaning greasy kitchensWipe the lens with a cloth dampened in mild soapy water, then dry it. Avoid solvents and abrasive pads, which can cloud the lens.
Every year (outdoor/damp areas)Look for insects, moisture or corrosion behind the trim and confirm any gaskets are intact.

The integrated LEDs are not user-replaceable bulbs. The rated light-source life of 54,000 hours works out to roughly 49 years at 3 hours a day, or about 12 years at 12 hours a day. Over time the LEDs gradually dim rather than burning out; when output becomes too low, or if the driver fails, replace the fixture or LED module as the manufacturer directs.

Troubleshooting

Most downlight problems trace back to dimmer compatibility or wiring connections. Always turn off the breaker before opening the fixture or the junction box.

ProblemPossible causeWhat to try
Light does not turn onBreaker off or tripped; loose wire connection; switch or dimmer failure.Check the breaker; with power off, confirm connections in the junction box are tight; test with a standard switch.
Flickers or buzzes when dimmedDimmer not compatible with the LED driver; dimmer low-end trim set too low; too many or too few fixtures on the dimmer.Use a dimmer on the manufacturer's compatibility list; adjust the dimmer's low-end trim; keep the load within the dimmer's LED rating.
Faint glow when switched offIlluminated or smart switch leaking a small current; shared neutral wiring issue.Try a standard switch; use a smart switch that has a neutral connection; have an electrician check the wiring.
Does not dim smoothly or turns off at low settingsDimmer range not matched to the driver.Raise the dimmer's minimum setting; consult the dimmer and fixture compatibility notes.
Color looks different from the other fixturesColor-temperature selector set differently from neighboring fixtures.Turn off power, check the selector setting and match it to the other fixtures.
Trim falls or hangs below the ceilingSprings or clips not engaged; opening cut too large.Reseat the springs in the receivers; use a trim with a wider flange or repair the drywall.
Turns off by itself after running a whileDriver overheating, often from insulation packed around a fixture or a loose connection.Turn off power and check the installation. Do not cover Non-IC fixtures with insulation; call an electrician if the problem continues.
Moisture inside the lensGasket not seated; fixture exposed to more water than its rating allows.Turn off power, dry the fixture and reseat the gasket; replace with a wet-rated fixture if needed.

Energy use and running costs

The Leadvision L111-08R04X draws 8 W. Used 3 hours a day — a typical home assumption — it consumes about 8.8 kWh a year, roughly $1.49 per year at an electricity price of $0.17 per kWh. In a commercial space lit 12 hours a day, the same fixture uses about 35 kWh, or $5.96 a year.

Efficacy — lumens of light per watt of electricity — is the best single measure of a fixture's efficiency. This model delivers 87.5 lm/W. That figure is better than 59% of the 3,089 Recessed models in our database.

Per fixture, at $0.17/kWh
Daily useEnergy per yearCost per year
1 hour2.9 kWh$0.50
3 hours8.8 kWh$1.49
6 hours17.5 kWh$2.98
12 hours35.0 kWh$5.96

The listed power factor is 0.86.

Dimming reduces power roughly in proportion to light output.

Frequently asked questions

How bright is the Leadvision L111-08R04X?

It is rated at 700 lumens while drawing 8 W, for an efficacy of 87.5 lumens per watt.

Is the Leadvision L111-08R04X dimmable?

Yes. It is continuously dimmable. Use a dimmer the manufacturer lists as compatible for flicker-free operation.

What color temperature is the Leadvision L111-08R04X?

It is selectable between 2700K, 3000K, 3500K, 4000K, and 5000K. Set the selector before installation.

What size is the Leadvision L111-08R04X?

Its nominal size is 4 in. Confirm the exact cutout or housing dimensions in the manufacturer's installation sheet before purchasing.

Can the Leadvision L111-08R04X touch insulation?

Yes. It is IC rated, which allows direct contact with thermal insulation.

Can I install the Leadvision L111-08R04X in a bathroom or shower?

It is wet-location rated, so it can be used where it may be exposed to water, including shower areas where the instructions permit. Follow local code for GFCI protection.

How much does it cost to run the Leadvision L111-08R04X?

At 3 hours a day and $0.17/kWh, it costs about $1.49 a year to operate.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified led downlights dataset published by the U.S. Environmental Protection Agency (record certified December 30, 2024), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with Leadvision. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact Leadvision or an authorized service provider for warranty repairs and replacement parts.

Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.