LED DownlightsRecessed
Liteline RA4-09SL-90- LED Downlight Manual
Setup, everyday use, maintenance and troubleshooting for the 4 in. recessed LED downlight, with verified specifications.
- Light output900 lumens
- Power9.6 W
- Efficacy93.8 lm/W
- Color temp.5000K
About the Liteline RA4-09SL-90-
The Liteline RA4-09SL-90- is a 4 in. recessed LED downlight certified under the ENERGY STAR program for light fixtures. It produces 900 lumens from 9.6 W of input power, an efficacy of 93.8 lumens per watt. That efficacy is better than 77% of the 3,089 Recessed models in our database.
Light quality: the fixture offers a 5000K color temperature (cool white) and a color rendering index of 92, which renders skin tones, wood and fabrics accurately.
Notable features include continuous dimming (0–10 V supported), a wet-location rating, an IC rating for direct contact with ceiling insulation, and an airtight housing rating. The rated light-source life is 54,000 hours.
Specifications
| Brand | Liteline |
|---|---|
| Model number | RA4-09SL-90-** |
| Model name / series | Luna |
| Fixture type | Recessed |
| Nominal size / aperture | 4 in. |
| Light output | 900 lumens |
| Input power | 9.6 W |
| Efficacy | 93.8 lm/W |
| Color temperature(s) | 5000K |
| Color rendering index (CRI) | 92 |
| Rated light-source life | 54,000 hours |
| Power factor | 0.97 |
| Continuously dimmable | Yes |
| Dimming control | 0–10 V |
| Location rating | Wet location |
| Indoor / outdoor use | Indoor |
| Insulation contact rating | IC |
| Airtight rated | Yes |
| Tunable / selectable white | Yes |
| Full-color tunable | No |
| Selectable light output | No |
| Occupancy sensor | No |
| Connected (smart) capable | No |
Safety information
- Turn off power at the circuit breaker — not just the wall switch — before installing, removing or servicing the fixture, and confirm the circuit is dead with a non-contact voltage tester.
- Installation must comply with the National Electrical Code (NEC) or Canadian Electrical Code (CEC) and local codes. Many jurisdictions require a licensed electrician and a permit for new fixture locations or new wiring; if you are not comfortable with household wiring, hire one.
- Use only the junction box, housing, or mounting hardware specified in the installation instructions, and do not exceed the box-fill limits of the junction box.
- Install the fixture only on a circuit whose voltage matches the label, and never modify the LED driver or module.
- Connect dimmable fixtures only to dimmers the manufacturer lists as compatible, and keep the total connected LED load within the dimmer's LED rating (often much lower than its incandescent rating).
Installation and first-time setup
Recessed downlights mount above the ceiling, either in a new-construction housing fixed to joists before the drywall goes up or in a remodel housing that clips into a cutout in an existing ceiling. This model is a 4 in. fixture; use the cutout template from the manufacturer — never estimate the hole size.
- Plan the layout
Check for joists, ducts and pipes before cutting. As a starting point for general lighting, space fixtures about as far apart as the ceiling is high, and keep them about half that distance from walls; use closer spacing or more lumens for task areas.
- Turn off power
Switch off the breaker feeding the circuit and verify it is dead.
- Cut the opening
Trace the template and cut the opening with a drywall saw or hole saw. Keep the cut clean so the trim covers it fully.
- Wire the junction box
Feed the supply cable into the fixture's junction box through a cable clamp. Connect line to line, neutral to neutral and ground to ground with listed connectors, and close the box cover.
- Set options
Check any selectors on the driver before the fixture goes into the ceiling.
- Install the fixture
Push the housing or canless module into the opening until the mounting clips or springs grip the drywall and the trim sits flush.
- Restore power and test
Turn on the breaker and check operation through the full dimming range.
Because this fixture is wet-location rated, it is suitable for locations exposed to water, such as covered porches, eaves and shower areas where the manual permits. Code requires fixtures within 3 ft horizontally and 8 ft vertically of a tub rim or shower threshold to be rated at least for damp locations — wet-location rated where subject to shower spray — and a GFCI-protected circuit is often required in these areas.
Using your downlight
Dimming
The fixture dims continuously. In addition to phase-cut (wall-box) dimming where supported, the certification data lists 0–10 V dimming. Check the manufacturer's compatibility list: most LED drivers work best with trailing-edge (ELV) or LED-rated dimmers, and some dimmers have a low-end trim adjustment that stops flicker at the bottom of the range.
0–10 V dimming uses a separate pair of low-voltage control wires (usually purple and gray, or purple and pink) run to a 0–10 V dimmer or lighting controller. Keep the control wiring separated from line-voltage conductors as the instructions and code require.
Light output and placement
At 900 lumens, this fixture is in the typical range for general lighting in kitchens, living areas and offices with 8–9 ft ceilings. LED fixtures reach full brightness instantly and are not shortened by frequent switching.
Care and maintenance
| When | What to do |
|---|---|
| Every 3–6 months | Dust the trim and lens with a soft, dry microfiber cloth with the light off and cool. Do not spray cleaner directly onto the fixture. |
| Every year | Check that the trim still sits flush and the springs or clips hold it firmly. A sagging trim can leave a gap that lets attic air leak. |
| When cleaning greasy kitchens | Wipe the lens with a cloth dampened in mild soapy water, then dry it. Avoid solvents and abrasive pads, which can cloud the lens. |
| Every year (outdoor/damp areas) | Look for insects, moisture or corrosion behind the trim and confirm any gaskets are intact. |
The integrated LEDs are not user-replaceable bulbs. The rated light-source life of 54,000 hours works out to roughly 49 years at 3 hours a day, or about 12 years at 12 hours a day. Over time the LEDs gradually dim rather than burning out; when output becomes too low, or if the driver fails, replace the fixture or LED module as the manufacturer directs.
Troubleshooting
Most downlight problems trace back to dimmer compatibility or wiring connections. Always turn off the breaker before opening the fixture or the junction box.
| Problem | Possible cause | What to try |
|---|---|---|
| Light does not turn on | Breaker off or tripped; loose wire connection; switch or dimmer failure. | Check the breaker; with power off, confirm connections in the junction box are tight; test with a standard switch. |
| Flickers or buzzes when dimmed | Dimmer not compatible with the LED driver; dimmer low-end trim set too low; too many or too few fixtures on the dimmer. | Use a dimmer on the manufacturer's compatibility list; adjust the dimmer's low-end trim; keep the load within the dimmer's LED rating. |
| Faint glow when switched off | Illuminated or smart switch leaking a small current; shared neutral wiring issue. | Try a standard switch; use a smart switch that has a neutral connection; have an electrician check the wiring. |
| Does not dim smoothly or turns off at low settings | Dimmer range not matched to the driver. | Raise the dimmer's minimum setting; consult the dimmer and fixture compatibility notes. |
| Color looks different from the other fixtures | Fixture has a different color temperature from neighboring fixtures. | Use fixtures with the same color temperature (this model is 5000K). |
| Trim falls or hangs below the ceiling | Springs or clips not engaged; opening cut too large. | Reseat the springs in the receivers; use a trim with a wider flange or repair the drywall. |
| Turns off by itself after running a while | Driver overheating, often from insulation packed around a fixture or a loose connection. | Turn off power and check the installation. Do not cover Non-IC fixtures with insulation; call an electrician if the problem continues. |
| Moisture inside the lens | Gasket not seated; fixture exposed to more water than its rating allows. | Turn off power, dry the fixture and reseat the gasket; replace with a wet-rated fixture if needed. |
Energy use and running costs
The Liteline RA4-09SL-90- draws 9.6 W. Used 3 hours a day — a typical home assumption — it consumes about 10.5 kWh a year, roughly $1.79 per year at an electricity price of $0.17 per kWh. In a commercial space lit 12 hours a day, the same fixture uses about 42 kWh, or $7.15 a year.
Efficacy — lumens of light per watt of electricity — is the best single measure of a fixture's efficiency. This model delivers 93.8 lm/W. That figure is better than 77% of the 3,089 Recessed models in our database.
| Daily use | Energy per year | Cost per year |
|---|---|---|
| 1 hour | 3.5 kWh | $0.60 |
| 3 hours | 10.5 kWh | $1.79 |
| 6 hours | 21.0 kWh | $3.57 |
| 12 hours | 42.0 kWh | $7.15 |
The listed power factor is 0.97, high enough that the fixture draws current efficiently from the supply — useful in commercial buildings with many fixtures on one circuit.
Dimming reduces power roughly in proportion to light output.
Frequently asked questions
How bright is the Liteline RA4-09SL-90-?
It is rated at 900 lumens while drawing 9.6 W, for an efficacy of 93.8 lumens per watt.
Is the Liteline RA4-09SL-90- dimmable?
Yes. It is continuously dimmable, and the certification data also lists 0–10 V dimming. Use a dimmer the manufacturer lists as compatible for flicker-free operation.
What color temperature is the Liteline RA4-09SL-90-?
It is a 5000K fixture with a CRI of 92.
What size is the Liteline RA4-09SL-90-?
Its nominal size is 4 in. Confirm the exact cutout or housing dimensions in the manufacturer's installation sheet before purchasing.
Can the Liteline RA4-09SL-90- touch insulation?
Yes. It is IC rated, which allows direct contact with thermal insulation, and it is also airtight rated to limit air leakage.
Can I install the Liteline RA4-09SL-90- in a bathroom or shower?
It is wet-location rated, so it can be used where it may be exposed to water, including shower areas where the instructions permit. Follow local code for GFCI protection.
How much does it cost to run the Liteline RA4-09SL-90-?
At 3 hours a day and $0.17/kWh, it costs about $1.79 a year to operate.
Sources and disclaimer
Specifications on this page come from the ENERGY STAR certified led downlights dataset published by the U.S. Environmental Protection Agency (record certified March 18, 2026), retrieved October 7, 2026.
The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with Liteline. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact Liteline or an authorized service provider for warranty repairs and replacement parts.
Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.
Report a problem with this guide
Spotted a wrong value, a broken link or something unclear? Tell us and we will review it.