LED DownlightsRecessed

WAC DS-**0834-*35*-** LED Downlight Manual

Setup, everyday use, maintenance and troubleshooting for the 8 in. recessed LED downlight, with verified specifications.

  • Light output3,850 lumens
  • Power34 W
  • Efficacy113 lm/W
  • Color temp.3500K

About the WAC DS-**0834-*35*-**

WAC model DS-**0834-*35*-** is an 8 in. recessed LED downlight that meets ENERGY STAR requirements for light output, efficacy and color quality. It produces 3,850 lumens from 34 W of input power, an efficacy of 113 lumens per watt. That efficacy is better than 97% of the 3,089 Recessed models in our database.

Light quality: the fixture offers a 3500K color temperature (neutral white) and a color rendering index of 82.

Notable features include continuous dimming. The rated light-source life is 55,000 hours.

Specifications

WAC DS-**0834-*35*-** specifications
BrandWAC
Model numberDS-**0834-*35*-**
Fixture typeRecessed
Nominal size / aperture8 in.
Light output3,850 lumens
Input power34.0 W
Efficacy113.2 lm/W
Color temperature(s)3500K
Color rendering index (CRI)82
Rated light-source life55,000 hours
Power factor0.98
Continuously dimmableYes
Indoor / outdoor useIndoor
Insulation contact ratingNon-IC
Airtight ratedNo
Tunable / selectable whiteNo
Full-color tunableNo
Selectable light outputNo
Occupancy sensorNo
Connected (smart) capableNo

Safety information

  • Turn off power at the circuit breaker — not just the wall switch — before installing, removing or servicing the fixture, and confirm the circuit is dead with a non-contact voltage tester.
  • Installation must comply with the National Electrical Code (NEC) or Canadian Electrical Code (CEC) and local codes. Many jurisdictions require a licensed electrician and a permit for new fixture locations or new wiring; if you are not comfortable with household wiring, hire one.
  • Use only the junction box, housing, or mounting hardware specified in the installation instructions, and do not exceed the box-fill limits of the junction box.
  • Install the fixture only on a circuit whose voltage matches the label, and never modify the LED driver or module.
  • Connect dimmable fixtures only to dimmers the manufacturer lists as compatible, and keep the total connected LED load within the dimmer's LED rating (often much lower than its incandescent rating).

Installation and first-time setup

Recessed downlights mount above the ceiling, either in a new-construction housing fixed to joists before the drywall goes up or in a remodel housing that clips into a cutout in an existing ceiling. This model is an 8 in. fixture; use the cutout template from the manufacturer — never estimate the hole size.

  1. Plan the layout

    Check for joists, ducts and pipes before cutting. As a starting point for general lighting, space fixtures about as far apart as the ceiling is high, and keep them about half that distance from walls; use closer spacing or more lumens for task areas.

  2. Turn off power

    Switch off the breaker feeding the circuit and verify it is dead.

  3. Cut the opening

    Trace the template and cut the opening with a drywall saw or hole saw. Keep the cut clean so the trim covers it fully.

  4. Wire the junction box

    Feed the supply cable into the fixture's junction box through a cable clamp. Connect line to line, neutral to neutral and ground to ground with listed connectors, and close the box cover.

  5. Set options

    Check any selectors on the driver before the fixture goes into the ceiling.

  6. Install the fixture

    Push the housing or canless module into the opening until the mounting clips or springs grip the drywall and the trim sits flush.

  7. Restore power and test

    Turn on the breaker and check operation through the full dimming range.

Using your downlight

Dimming

The fixture dims continuously. Check the manufacturer's compatibility list: most LED drivers work best with trailing-edge (ELV) or LED-rated dimmers, and some dimmers have a low-end trim adjustment that stops flicker at the bottom of the range.

Light output and placement

At 3,850 lumens, this is a high-output fixture suited to tall ceilings, lobbies, retail and other commercial spaces. LED fixtures reach full brightness instantly and are not shortened by frequent switching.

Care and maintenance

WhenWhat to do
Every 3–6 monthsDust the trim and lens with a soft, dry microfiber cloth with the light off and cool. Do not spray cleaner directly onto the fixture.
Every yearCheck that the trim still sits flush and the springs or clips hold it firmly. A sagging trim can leave a gap that lets attic air leak.
When cleaning greasy kitchensWipe the lens with a cloth dampened in mild soapy water, then dry it. Avoid solvents and abrasive pads, which can cloud the lens.

The integrated LEDs are not user-replaceable bulbs. The rated light-source life of 55,000 hours works out to roughly 50 years at 3 hours a day, or about 13 years at 12 hours a day. Over time the LEDs gradually dim rather than burning out; when output becomes too low, or if the driver fails, replace the fixture or LED module as the manufacturer directs.

Troubleshooting

Most downlight problems trace back to dimmer compatibility or wiring connections. Always turn off the breaker before opening the fixture or the junction box.

ProblemPossible causeWhat to try
Light does not turn onBreaker off or tripped; loose wire connection; switch or dimmer failure.Check the breaker; with power off, confirm connections in the junction box are tight; test with a standard switch.
Flickers or buzzes when dimmedDimmer not compatible with the LED driver; dimmer low-end trim set too low; too many or too few fixtures on the dimmer.Use a dimmer on the manufacturer's compatibility list; adjust the dimmer's low-end trim; keep the load within the dimmer's LED rating.
Faint glow when switched offIlluminated or smart switch leaking a small current; shared neutral wiring issue.Try a standard switch; use a smart switch that has a neutral connection; have an electrician check the wiring.
Does not dim smoothly or turns off at low settingsDimmer range not matched to the driver.Raise the dimmer's minimum setting; consult the dimmer and fixture compatibility notes.
Color looks different from the other fixturesFixture has a different color temperature from neighboring fixtures.Use fixtures with the same color temperature (this model is 3500K).
Trim falls or hangs below the ceilingSprings or clips not engaged; opening cut too large.Reseat the springs in the receivers; use a trim with a wider flange or repair the drywall.
Turns off by itself after running a whileDriver overheating, often from insulation packed around a fixture or a loose connection.Turn off power and check the installation. Do not cover Non-IC fixtures with insulation; call an electrician if the problem continues.

Energy use and running costs

The WAC DS-**0834-*35*-** draws 34 W. Used 3 hours a day — a typical home assumption — it consumes about 37.2 kWh a year, roughly $6.33 per year at an electricity price of $0.17 per kWh. In a commercial space lit 12 hours a day, the same fixture uses about 149 kWh, or $25.32 a year.

Efficacy — lumens of light per watt of electricity — is the best single measure of a fixture's efficiency. This model delivers 113 lm/W. That figure is better than 97% of the 3,089 Recessed models in our database.

Per fixture, at $0.17/kWh
Daily useEnergy per yearCost per year
1 hour12.4 kWh$2.11
3 hours37.2 kWh$6.33
6 hours74.5 kWh$12.66
12 hours148.9 kWh$25.32

The listed power factor is 0.98, high enough that the fixture draws current efficiently from the supply — useful in commercial buildings with many fixtures on one circuit.

Dimming reduces power roughly in proportion to light output.

Frequently asked questions

How bright is the WAC DS-**0834-*35*-**?

It is rated at 3,850 lumens while drawing 34 W, for an efficacy of 113 lumens per watt.

Is the WAC DS-**0834-*35*-** dimmable?

Yes. It is continuously dimmable. Use a dimmer the manufacturer lists as compatible for flicker-free operation.

What color temperature is the WAC DS-**0834-*35*-**?

It is a 3500K fixture with a CRI of 82.

What size is the WAC DS-**0834-*35*-**?

Its nominal size is 8 in. Confirm the exact cutout or housing dimensions in the manufacturer's installation sheet before purchasing.

Can the WAC DS-**0834-*35*-** touch insulation?

No. It is Non-IC rated, so insulation must be kept at least 3 in. away from the fixture.

How much does it cost to run the WAC DS-**0834-*35*-**?

At 3 hours a day and $0.17/kWh, it costs about $6.33 a year to operate.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified led downlights dataset published by the U.S. Environmental Protection Agency (record certified March 31, 2025), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with WAC. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact WAC or an authorized service provider for warranty repairs and replacement parts.

Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.