Geothermal Heat PumpsOpen Loop Water-to-Air
York QD024-1CFC-*****A Geothermal Heat Pump Manual
Setup, everyday use, maintenance and troubleshooting for the open-loop water-to-air geothermal heat pump, with verified specifications.
- ConfigurationOpen Loop Water-to-Air
- Heating COP4.2
- Cooling EER24.3
- Heat cost per million Btu$11.86
About the York QD024-1CFC-*****A
This guide covers the York QD024-1CFC-*****A from the RF line, an open-loop water-to-air geothermal heat pump that meets ENERGY STAR efficiency requirements.
In this configuration it is rated at a heating COP of 4.2 and a cooling EER of 24.3. A COP of 4.2 means it delivers about 4.2 units of heat for every unit of electricity it uses. An EER of 24.3 means it removes 24.3 Btu of heat per watt-hour in cooling. Open-loop ratings are measured with 59 °F (15 °C) water entering the heat pump in cooling and 50 °F (10 °C) in heating, simulating well water. That warmer winter source is why open-loop figures run higher than closed-loop figures for the same hardware.
As a water-to-air unit it heats and cools through ductwork like a conventional furnace and air conditioner, with the outdoor condenser replaced by the ground loop. Among peers, its EER beats 40% of 1,510 Open Loop Water-to-Air models.
It is also recognized as ENERGY STAR Most Efficient, the program's designation for the top-performing certified products in a category.
Specifications
| Brand | York |
|---|---|
| Model number | QD024-1CFC-*****A |
| Model name / series | RF |
| Configuration | Open Loop Water-to-Air |
| Product series | RF |
| EER (cooling efficiency) | 24.3 Btu/Wh |
| COP (heating efficiency) | 4.2 |
| ENERGY STAR Most Efficient | Yes |
Certified ratings by application
2 certified rating configurations are listed for the York QD024-1CFC-*****A, sorted by COP. Ratings depend on the application, so compare the row that matches your installation.
| Application | EER | COP | Certified |
|---|---|---|---|
| Open Loop Water-to-Air | 24.3 | 4.2 | July 2026 |
| Closed Loop Water-to-Air | 19.9 | 3.8 | June 2026 |
Safety information
- Installation, refrigerant work and electrical connections must be done by a licensed HVAC contractor experienced with geothermal systems, following the manufacturer's instructions and local codes. Most jurisdictions require permits for the heat pump and for drilling or trenching.
- Geothermal heat pumps typically run on a 208/230 V circuit. Switch off the disconnect and the breaker before opening any access panel; capacitors can hold a dangerous charge after power is removed.
- Call 811 (or your local utility-locate service) before any digging so buried gas, electric and water lines are marked.
- Do not operate the unit with access panels or the blower door removed.
- Open-loop systems draw from and return water to an aquifer or surface water. Wells and discharge methods are regulated in most states — use a licensed well driller and follow local discharge and permitting rules.
- If your home also has a fuel-burning furnace, boiler or water heater, keep carbon monoxide alarms on every level and near sleeping areas.
Installation and first-time setup
A geothermal system is only as good as its ground connection. The ratings for the York QD024-1CFC-*****A assume correct source-side flow and temperatures, so the loop or well design deserves as much attention as the heat pump itself.
- Room-by-room load calculation
Insist on an ACCA Manual J heat-loss and heat-gain calculation. Geothermal equipment and loops are expensive to oversize, and an undersized loop drives entering-water temperatures down in winter, reducing capacity and efficiency.
- Well yield and water quality
An open loop needs a reliable well with enough yield for the heat pump at full load, plus a legal way to return the water (a return well or approved surface discharge). Test the water for iron, hardness, pH and sediment — poor water quality fouls the heat exchanger and may call for a cupronickel coil or a closed loop instead.
- Pump and flow control
The well pump should be sized for the heat pump's required flow, and a flow-control or solenoid valve should stop water flow whenever the compressor is off so you are not pumping water for nothing.
- Ductwork and airflow
Have the contractor measure external static pressure and set blower airflow to the manufacturer's table (commonly 350–450 CFM per ton). Leaky or undersized ducts are the most common reason a new system underperforms.
- Verify water flow
Source-side flow must match the manufacturer's table — closed loops commonly run about 2.5–3 gpm per ton, while open loops often use less. Ask the installer to record flow and the temperature difference across the heat exchanger.
- Commissioning
Ask for a start-up report that records entering and leaving source temperatures, refrigerant pressures, airflow or load-side flow, thermostat and auxiliary-heat settings, and the loop fluid freeze point where applicable.
Using your geothermal heat pump
Thermostat settings
Choose a comfortable setpoint and leave it. Geothermal heat pumps work best holding a steady temperature; large setbacks in heating mode can bring on auxiliary electric heat during recovery, which costs several times more per hour than the compressor. If you use setbacks, keep them to a few degrees or use a thermostat with heat-pump adaptive recovery.
Auxiliary and emergency heat
Many water-to-air systems include electric resistance backup. "Auxiliary" heat should come on only during very cold weather or quick recovery; "emergency" heat locks out the compressor and should be used only if the heat pump fails. Frequent auxiliary heat in mild weather is worth a service call.
Cooling and humidity
Set the fan to "Auto" in summer so moisture collected on the indoor coil drains away instead of re-evaporating into the house. Supply air in heating mode is often around 90–105 °F — cooler than a gas furnace — so the air from the registers may feel mild even though the house is being heated properly.
Domestic hot water
Many geothermal units can be fitted with a desuperheater that preheats domestic hot water using waste heat from the compressor. If your installation has one, its circulator runs only when the compressor runs, and the water heater still provides final heating — check with your installer whether it was included.
Care and maintenance
Ground loops have no outdoor coil to clean and are largely maintenance-free, but the indoor unit and the source-side fluid still need periodic attention.
| When | What to do |
|---|---|
| Every 1–3 months | Inspect the air filter and replace it when dirty (1 in. filters usually monthly to quarterly; 4–5 in. media filters every 6–12 months). |
| Every season | Check that the condensate drain and trap are clear (water-to-air units remove moisture in cooling mode) and that nothing is stored against the unit's access panels. |
| Every year | Professional service: clean any strainer, check well-pump operation and flow, and compare water temperature drop across the heat exchanger. Mineral scaling or iron fouling may call for acid cleaning of the coaxial heat exchanger. |
| Every 3–5 years | Have the indoor coil and blower (or load-side heat exchanger) inspected and cleaned if airflow or temperature split has dropped. |
Troubleshooting
Geothermal heat pumps protect themselves with pressure and temperature switches, so most "no heat" calls trace back to airflow, water flow or thermostat settings. Work through the checks below before calling a technician.
| Problem | Possible cause | What to try |
|---|---|---|
| No heating or cooling | Thermostat in wrong mode; tripped breaker; disconnect off; unit in safety lockout. | Check mode and setpoint; reset the breaker once. Many units clear a lockout when power is cycled off and on — if it locks out again, call for service. |
| Unit locks out in heating mode | Low source-side flow; entering water too cold; low antifreeze concentration; dirty air filter. | Replace the filter and confirm loop or well pumps run. Repeated low-temperature lockouts point to a flow, antifreeze or loop-sizing problem for a technician. |
| Unit locks out in cooling mode | High head pressure from low water flow, a scaled heat exchanger or poor airflow. | Check the filter and blower; have a technician verify flow and the temperature rise across the heat exchanger. |
| High electric bills in winter | Auxiliary heat running too often; deep thermostat setbacks; loop delivering cold water. | Reduce setbacks and ask your contractor to review auxiliary-heat staging and entering-water temperatures. |
| Air from vents feels lukewarm | Normal heat-pump supply temperature (around 90–105 °F). | Judge comfort by whether the house reaches setpoint, not by the feel of the air. |
| Gurgling or rushing water sounds | Air trapped in the loop or hydronic piping. | A technician should purge the air; persistent air may mean a slow leak. |
| Water near the unit | Clogged condensate drain or trap; leaking fitting. | Turn the unit off, clear the drain and check fittings; call for service if water continues. |
| Rusty or slimy deposits; falling capacity | Iron bacteria, iron or scale from the well water fouling the heat exchanger. | Have the water tested and the heat exchanger cleaned; discuss water treatment or a closed loop if fouling recurs. |
Energy use and running costs
At its rated COP of 4.2, the York QD024-1CFC-*****A uses about 70 kWh of electricity per million Btu of heat delivered — roughly $11.86 at $0.17 per kWh.
| Heat source | Energy used | Estimated cost |
|---|---|---|
| This heat pump (COP 4.2) | 3,489 kWh | $593 |
| Electric resistance heat (COP 1.0) | 14,654 kWh | $2,491 |
| 95% AFUE gas furnace | 526 therms | $789 |
| 80% AFUE gas furnace | 625 therms | $938 |
For cooling, an EER of 24.3 means each ton of capacity (12,000 Btu/h) draws about 0.49 kW at the rating point. Over 1,000 full-load cooling hours a year — an assumption typical of a mixed U.S. climate — that is about 494 kWh per ton, or $83.95 per ton at $0.17 per kWh. Multiply by your system's tonnage for a seasonal estimate.
These figures are based on the certified rating point. Real-world performance changes with well-water temperature and pumping depth, and the published ratings include only a small allowance for pumping — the full energy of the well pump is extra. A correctly sized well pump that shuts off with the compressor keeps that penalty small.
Frequently asked questions
What are the efficiency ratings of the York QD024-1CFC-*****A?
In its open-loop water-to-air configuration it is rated at an EER of 24.3 for cooling and a COP of 4.2 for heating. Open-loop ratings use 59 °F entering water for cooling and 50 °F for heating.
Can the York QD024-1CFC-*****A be used with both open and closed loops?
This listing covers its open-loop rating. Manufacturers often certify the same water-source unit separately for closed-loop and open-loop use, each with its own EER and COP, so check the York literature (or other listings for model QD024-1CFC-*****A) for the configuration you plan to install.
How much does it cost to heat with the York QD024-1CFC-*****A?
At a COP of 4.2 it needs about 70 kWh per million Btu of heat, or about $11.86 at $0.17/kWh. A home needing 50 million Btu a year would spend roughly $593, before loop-pump energy and any auxiliary heat.
Does the York QD024-1CFC-*****A heat with forced air or hot water?
Forced air. It is an open-loop water-to-air unit, so it delivers heating and cooling through ductwork with an indoor blower, like a furnace and central air conditioner.
Is the York QD024-1CFC-*****A ENERGY STAR certified?
Yes. It appears on the ENERGY STAR certified geothermal heat pump list, with a certification date of July 2026, and it is also designated ENERGY STAR Most Efficient.
Sources and disclaimer
Specifications on this page come from the ENERGY STAR certified geothermal heat pumps dataset published by the U.S. Environmental Protection Agency (record certified July 20, 2026), retrieved October 7, 2026.
The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with York. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact York or an authorized service provider for warranty repairs and replacement parts.
Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.