Setup, everyday use, maintenance and troubleshooting for the 0.8 hp pressure-cleaner booster pump, with verified specifications.

  • WEF0.62 kgal/kWh
  • SpeedSingle-speed
  • Rated horsepower0.8 hp
  • Est. yearly cost$169

About the Pentair 360546

This guide covers the Pentair 360546, a 0.8 hp pressure-cleaner booster pump from the HydroBoost line on the ENERGY STAR certified list.

Its Weighted Energy Factor (WEF) is 0.62, meaning it moves about 620 gallons of water for each kilowatt-hour of electricity under the DOE test. The federal minimum for a pump of its type and size is 0.45, so it is about 38% more efficient than the least efficient pump allowed. Its WEF is higher than 22% of the 10 pool pump models in our database.

At its test point it delivers 10.0 gpm against 128 ft of head while drawing 909 W at 3,417 rpm — the high-pressure, low-flow duty a pressure-side cleaner needs. A booster pump does not filter water; it takes water from the filter pump's return line and raises its pressure to drive the cleaner, so it must only run while the main filter pump is running.

It uses a permanent split capacitor (PSC) motor with a rated output of 0.8 hp (0.32 hydraulic horsepower).

Specifications

Pentair 360546 specifications
BrandPentair
Model number360546
Model name / seriesHydroBoost
Pump typePressure Cleaner Booster
Motor speed designSingle-speed
Motor constructionPermanent split capacitor (PSC)
Rated horsepower0.80 hp
Hydraulic horsepower0.324 hhp
Weighted Energy Factor (WEF)0.62 kgal/kWh
Federal minimum WEF for this pump0.45 kgal/kWh
Better than federal minimum38%
Low-flow test point flow10.0 gpm
Low-flow test point head127.7 ft
Low-flow test point speed3,417 rpm
Low-flow test point power909 W
Freeze protectionNo
Connected functionalityNo

Safety information

  • Pool pump wiring must be installed by a qualified electrician in accordance with the National Electrical Code (Article 680) and local codes, including GFCI protection and a disconnect within sight of the pump.
  • Connect the pump's bonding lug to the pool's equipotential bonding grid with a solid copper conductor (at least 8 AWG). Bonding reduces shock hazards in and around the water; never remove it.
  • Turn off power at the breaker before servicing the pump, and wait for the time stated on the label before touching the drive of a variable-speed motor.
  • Before opening the strainer lid or the filter, turn the pump off and open the filter's air-relief valve to release pressure. A filter or lid opened under pressure can separate violently.
  • Never operate the pool with missing, broken or loose drain or suction-outlet covers. Suction can trap hair, limbs or bodies; know where the pump's emergency shut-off is.
  • Never run the pump dry. Running without water destroys the shaft seal and can melt plastic housings.
  • Store pool chemicals away from the pump and motor, and never add chemicals directly into the skimmer while the pump is running unless the product label says it is safe.
  • Run the booster pump only while the main filter pump is running and circulating water; running it alone can damage the booster within minutes.

Installation and first-time setup

How the Pentair 360546 is plumbed and programmed matters as much as its rating. Use these steps as a checklist with your pool professional.

  1. Plumb from the filter return

    A booster pump draws from the return side of the filtration system and feeds the dedicated cleaner line. Follow the manufacturer's plumbing diagram and mount it on a level pad near the filter equipment.

  2. Plumbing

    Use the pipe size the manufacturer recommends, keep elbows to a minimum and leave a straight run of pipe ahead of the pump inlet. Lower plumbing resistance (head) means more flow per watt. Install unions and valves so the pump can be isolated and removed.

  3. Electrical

    Confirm the supply voltage matches the pump's nameplate and any voltage selection on the motor, provide GFCI protection, and connect the bonding conductor. Ask the electrician to tighten and inspect all connections at start-up.

Using your pool pump

Running the cleaner

Most pressure-side cleaners need only a few hours of operation a day. Schedule the booster to start after the filter pump has been running for several minutes and to stop before it shuts off. At about 909 W, each hour of booster run time uses roughly 0.91 kWh.

Care and maintenance

WhenWhat to do
WeeklyCheck the cleaner's in-line filter screen and the main pump's baskets; restricted supply makes the booster noisy and the cleaner sluggish.
MonthlyLook for drips under the booster and listen for changes in sound while it runs.
Every seasonKeep leaves and debris away from the motor's cooling vents and check that the bonding wire is still attached.
Before freezing weatherDrain the booster with its drain plug when the pool is winterized.
Every yearHave connections and the motor checked; replace the shaft seal at the first sign of leaking, and have the capacitor tested if the motor is slow to start.

Troubleshooting

Most booster problems trace back to the main filter pump, the cleaner line or the electrical supply. Always turn off power before working on the pump.

ProblemPossible causeWhat to try
Booster will not startBreaker or GFCI tripped; timer or automation not calling; failed capacitor.Check the schedule and the breaker (reset a GFCI once only). If the motor hums without turning, have the capacitor tested.
Booster is loud or rattlesMain filter pump off or running too slowly; restricted supply from a dirty filter.Make sure the filter pump is running at an adequate speed and clean the filter.
Cleaner moves slowly or stallsClogged in-line cleaner screen; leaking or kinked cleaner hose; worn cleaner parts.Clean the screen, inspect the hose and check the cleaner for wear.
Water leaking from the boosterWorn shaft seal or loose fitting.Replace the seal or tighten the fitting before water reaches the motor.
High-pitched squeal or grindingWorn motor bearings.Turn the booster off and have the motor serviced or replaced.
Motor shuts off after running a whileOverheating from blocked vents or low voltage; thermal overload tripping.Clear the vents and have an electrician check the supply voltage.

Energy use and running costs

Assuming the Pentair 360546 runs 3 hours a day, every day of the year, at its rated 909 W, it would use about 995 kWh per year — roughly $169 at $0.17 per kWh.

Every hour you trim from the daily schedule saves about 332 kWh ($56.40) a year. A seasonal pool that runs the cleaner only half the year would use about half as much.

Frequently asked questions

What is the WEF rating of the Pentair 360546?

The Pentair 360546 has a Weighted Energy Factor of 0.62 thousand gallons per kWh, compared with a federal minimum of 0.45 for its type and size — about 38% better.

How much electricity does the Pentair 360546 use?

It draws about 909 W at its rated point. Running 3 hours a day year-round, that is about 995 kWh, or $169 a year at $0.17/kWh.

What horsepower is the Pentair 360546?

It has a rated horsepower of 0.8 hp and a hydraulic horsepower of 0.32 hhp — the power it actually delivers to the water at its rating point.

Can the Pentair 360546 run without the filter pump?

No. A pressure-cleaner booster pump relies on water supplied by the filter pump. Interlock or schedule it so it runs only while the filter pump is on.

Is the Pentair 360546 ENERGY STAR certified?

Yes. It appears on the ENERGY STAR certified pool pump list, with a certification date of April 2025.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified pool pumps dataset published by the U.S. Environmental Protection Agency (record certified April 2, 2025), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with Pentair. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact Pentair or an authorized service provider for warranty repairs and replacement parts.

Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.