Pool PumpsAbove-Ground Filter Pump

Tr�vi SPH130-VS Pool Pump Manual

Setup, everyday use, maintenance and troubleshooting for the 1.3 hp variable-speed above-ground pool pump, with verified specifications.

  • WEF11.32 kgal/kWh
  • SpeedVariable-speed
  • Rated horsepower1.3 hp
  • Est. yearly cost$110

About the Tr�vi SPH130-VS

The Tr�vi SPH130-VS is a 1.3 hp variable-speed above-ground pool pump, certified under the ENERGY STAR program.

Its Weighted Energy Factor (WEF) is 11.32, meaning it moves about 11,320 gallons of water for each kilowatt-hour of electricity under the DOE test. The federal minimum for a pump of its type and size is 4.43, so it is about 156% more efficient than the least efficient pump allowed. Its WEF is higher than 74% of the 74 above-ground filter pump models in our database.

At full speed on the DOE reference system curve C it moves about 65 gpm while drawing 990 W. At its low-speed test point it moves 24.9 gpm against 5.1 ft of head using 67 W at 1,254 rpm, compared with 51.8 gpm at 519 W at its high-speed test point. That works out to about 22.2 gallons per watt-hour at low speed versus 6.0 at high speed. That gap is the reason variable-speed pumps save so much energy: power falls roughly with the cube of motor speed, so running longer at a low speed filters the same water for a fraction of the electricity.

It uses an electronically commutated (ECM) motor with a rated output of 1.3 hp (0.56 hydraulic horsepower). Standby power is listed at 5 W.

Specifications

Tr�vi SPH130-VS specifications
BrandTr�vi
Model numberSPH130-VS
Pump typeAbove-Ground Filter Pump
Motor speed designVariable-speed
Motor constructionElectronically commutated (ECM)
Rated horsepower1.30 hp
Hydraulic horsepower0.558 hhp
Weighted Energy Factor (WEF)11.32 kgal/kWh
Federal minimum WEF for this pump4.43 kgal/kWh
Better than federal minimum156%
Flow at full speed (DOE curve C)64.7 gpm
Power at full speed (DOE curve C)990 W
High-flow test point flow51.8 gpm
High-flow test point head22.2 ft
High-flow test point speed2,746 rpm
High-flow test point power519 W
Low-flow test point flow24.9 gpm
Low-flow test point head5.1 ft
Low-flow test point speed1,254 rpm
Low-flow test point power67.1 W
Standby power5 W
Freeze protectionNo
Connected functionalityNo

Safety information

  • Pool pump wiring must be installed by a qualified electrician in accordance with the National Electrical Code (Article 680) and local codes, including GFCI protection and a disconnect within sight of the pump.
  • Connect the pump's bonding lug to the pool's equipotential bonding grid with a solid copper conductor (at least 8 AWG). Bonding reduces shock hazards in and around the water; never remove it.
  • Turn off power at the breaker before servicing the pump, and wait for the time stated on the label before touching the drive of a variable-speed motor.
  • Before opening the strainer lid or the filter, turn the pump off and open the filter's air-relief valve to release pressure. A filter or lid opened under pressure can separate violently.
  • Never operate the pool with missing, broken or loose drain or suction-outlet covers. Suction can trap hair, limbs or bodies; know where the pump's emergency shut-off is.
  • Never run the pump dry. Running without water destroys the shaft seal and can melt plastic housings.
  • Store pool chemicals away from the pump and motor, and never add chemicals directly into the skimmer while the pump is running unless the product label says it is safe.

Installation and first-time setup

How the Tr�vi SPH130-VS is plumbed and programmed matters as much as its rating. Use these steps as a checklist with your pool professional.

  1. Mount below the water level

    Non-self-priming pumps must sit below the pool's water level so water flows into the pump by gravity (flooded suction). Place it on a level, solid base near the pool, out of standing water.

  2. Plumbing

    Use the pipe size the manufacturer recommends, keep elbows to a minimum and leave a straight run of pipe ahead of the pump inlet. Lower plumbing resistance (head) means more flow per watt. Install unions and valves so the pump can be isolated and removed.

  3. Electrical

    Confirm the supply voltage matches the pump's nameplate and any voltage selection on the motor, provide GFCI protection, and connect the bonding conductor. Ask the electrician to tighten and inspect all connections at start-up.

  4. Prime the pump

    Fill the strainer housing with water, seal the lid, open the suction and return valves and start the pump (most variable-speed drives run a high-speed priming period automatically). Open the filter's air-relief valve until a steady stream of water appears. A non-self-priming pump should fill and run almost immediately.

  5. Program speeds and schedules

    Set a daily schedule with long periods at low speed for filtration and short periods at higher speed only where needed. Check the minimum flow required by a heater, salt chlorine generator, suction cleaner or spa spillover, and set those speeds just high enough to satisfy them.

Using your pool pump

How long to run the pump

Most residential pools are circulated at about one full turnover (the pool's volume) per day, adjusted for bather load, debris and water clarity. With this pump, achieve that turnover over more hours at low speed rather than fewer hours at high speed.

For example, at its low-speed test-point flow of 24.9 gpm, turning over a 20,000-gallon pool would take about 13.4 hours and use about 0.9 kWh. Real plumbing usually has more resistance than the test point, so measure your actual flow if your system has a flow meter.

Choosing speeds

Find the lowest speed that keeps the skimmers drawing, the water clear and any heater or chlorinator satisfied, and use that for most of the day. Raise speed only for tasks that need it, such as vacuuming, running a suction cleaner or operating water features.

Care and maintenance

WhenWhat to do
WeeklyEmpty the pump strainer basket and skimmer baskets. A clogged basket starves the pump of water and can damage the seal.
MonthlyInspect the strainer-lid O-ring; clean it and apply a silicone-based lubricant (not petroleum jelly). Look for drips under the pump and air in the strainer.
When filter pressure rises 8–10 psi above cleanBackwash or clean the filter. A dirty filter forces the pump to work harder and reduces flow.
Every seasonKeep leaves, mulch and debris away from the motor's cooling vents, and check that the bonding wire is still attached.
Before freezing weatherDrain the pump and hoses, and store the pump indoors for the winter.
Every yearHave connections and the motor checked; replace the shaft seal at the first sign of leaking between the pump and motor.

Troubleshooting

Most pump problems trace back to air leaks, low water or blocked baskets. Always turn off power before opening the pump.

ProblemPossible causeWhat to try
Pump will not primeLow water level; air leak on the suction side (lid O-ring, unions, valves); clogged basket or impeller; closed valve.Top up the pool, clean and lubricate the lid O-ring, check valves and unions, and clear the basket and impeller.
Air bubbles in the strainer or returnsSuction-side air leak; water level below the skimmer opening.Tighten unions, replace a worn lid O-ring and raise the water level.
Low flow with high filter pressureDirty filter; partially closed return valve.Backwash or clean the filter and check return valves.
Low flow with low filter pressureClogged skimmer, strainer basket or impeller; suction blockage.Empty baskets and check the impeller for debris with the power off.
Gravelly or rattling noiseCavitation from restricted suction or a speed set too high for the plumbing.Clear suction blockages and lower the speed.
High-pitched squeal or grindingWorn motor bearings.Turn the pump off and have the motor serviced or replaced.
Water leaking between pump and motorWorn shaft seal.Replace the seal promptly so water does not reach the motor bearings.
Drive shows an error or the pump will not startDrive fault, overheating, voltage problem or a programmed schedule off period.Check the schedule and the code shown; look up the code in your manufacturer's manual.

Energy use and running costs

Assume a 20,000-gallon pool circulated at one full turnover a day, 365 days a year (7,300 thousand gallons pumped). At its WEF of 11.32, the Tr�vi SPH130-VS would use about 645 kWh per year — roughly $110 at $0.17 per kWh.

Electricity to pump 7,300 thousand gallons a year at $0.17 per kWh.
PumpWEFEnergyCost
This model11.32645 kWh$110
Pump at the federal minimum4.431,648 kWh$280

A pool open only six months a year would use about half these amounts. WEF reflects the DOE test schedule, which weights most operating hours at low speed; your actual use depends on your schedule, plumbing resistance, filter condition and equipment such as heaters or cleaners that need higher flow.

Standby power of 5 W adds up to about 44 kWh a year if the pump stays powered around the clock while idle.

Frequently asked questions

What is the WEF rating of the Tr�vi SPH130-VS?

The Tr�vi SPH130-VS has a Weighted Energy Factor of 11.32 thousand gallons per kWh, compared with a federal minimum of 4.43 for its type and size — about 156% better.

How much does it cost to run the Tr�vi SPH130-VS?

Circulating a 20,000-gallon pool once a day all year would take about 645 kWh, or about $110 at $0.17/kWh. A seasonal pool would use proportionally less.

Is the Tr�vi SPH130-VS a variable-speed pump?

Yes. It is a variable-speed pump with an electronically commutated (ECM) motor, so you can set the exact speed for each task.

What horsepower is the Tr�vi SPH130-VS?

It has a rated horsepower of 1.3 hp and a hydraulic horsepower of 0.56 hhp — the actual water-moving power at full speed on DOE reference curve C, which determines its federal efficiency class.

How much water does the Tr�vi SPH130-VS pump?

At full speed on DOE reference curve C it moves about 65 gpm. At its low-speed test point it moves 24.9 gpm using 67 W. Actual flow depends on your pipe size, filter and fittings.

Does the Tr�vi SPH130-VS have freeze protection?

Built-in freeze protection is not listed for this model. In freezing climates, use an automation system with freeze protection or winterize the equipment.

Is the Tr�vi SPH130-VS ENERGY STAR certified?

Yes. It appears on the ENERGY STAR certified pool pump list, with a certification date of October 2024.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified pool pumps dataset published by the U.S. Environmental Protection Agency (record certified October 7, 2024), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with Tr�vi. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact Tr�vi or an authorized service provider for warranty repairs and replacement parts.

Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.