RefrigeratorsTop Freezer
Summit LTM10W Refrigerator Manual
Setup, everyday use, maintenance and troubleshooting for the 10 cu. ft. top-freezer refrigerator, with verified specifications.
- Capacity10 cu. ft.
- StyleTop Freezer
- Energy use296 kWh/yr
- Est. yearly cost$50.32
About the Summit LTM10W
This guide covers the Summit LTM10W, a 10 cu. ft. top-freezer refrigerator listed as ENERGY STAR certified. The cabinet measures 59.8 in. high and 23.4 in. wide.
It uses automatic defrost, so frost is cleared on a timed cycle without any action from you.
Rated energy consumption is 296 kWh per year, 11% below the U.S. federal maximum for its product class. That is lower than 96% of the 728 Top Freezer models in our database.
Specifications
| Brand | Summit |
|---|---|
| Model number | LTM10W |
| Configuration | Top Freezer |
| Total capacity | 10.0 cu. ft. |
| Adjusted volume | 12.1 cu. ft. |
| Height | 59.8 in. |
| Width | 23.4 in. |
| Defrost type | Automatic |
| Automatic ice maker | No |
| Through-the-door dispenser | No |
| Counter-depth design | No |
| Built-in installation | No |
| Annual energy use | 296 kWh/yr |
| U.S. federal standard | 331 kWh/yr |
| Better than federal standard | 11% |
| Smart / connected features | No |
| Refrigerant | R-600a (GWP:3 | Lower GWP) |
| DOE product class | 3 - Refrigerator-freezers - automatic defrost with top-mounted freezer without an automatic ice maker |
| ENERGY STAR Most Efficient | Yes |
Safety information
- Plug the unit into a dedicated, grounded 115 V / 60 Hz outlet. Do not use an extension cord, adapter plug or a GFCI-protected kitchen circuit unless local code requires it.
- Use two or more people to move and install the appliance; a refrigerator is top-heavy when the doors are open.
- Never let children climb, sit or stand on shelves, drawers or doors.
- Before disposing of an old refrigerator, remove the doors and leave the shelves in place so children cannot become trapped inside.
- Unplug the unit (or switch off the breaker) before replacing a light bulb, cleaning the condenser or performing any repair.
Installation and first-time setup
Measure the installation space and every doorway on the delivery path before the unit arrives. This model is 23.4 in. wide and 59.8 in. tall; allow about 1 in. of extra width and height in the opening so air can circulate and the doors can swing past adjacent cabinets.
- Choose the location
Pick a level floor away from ovens, heating vents and direct sunlight. Room temperature between 55 °F and 110 °F (13–43 °C) keeps the compressor working in its design range — avoid unheated garages in winter unless the manufacturer rates the model for garage use.
- Unpack and inspect
Remove all tape, foam and shipping blocks, including any compressor shipping bolts noted on a tag at the rear. Check that the cabinet and doors are undamaged.
- Let it stand
If the refrigerator was transported on its side, stand it upright for at least four hours (overnight is better) before plugging it in so compressor oil can drain back.
- Level the cabinet
Adjust the front leveling legs or rollers so the cabinet is level side to side and tilted very slightly backward. This helps the doors close by themselves and seal properly.
- Power on and cool down
Plug in the unit and leave the controls at the factory setting. Allow 12–24 hours for the cabinet to reach temperature before loading fresh food.
Using your refrigerator
Recommended temperature settings
| Compartment | Target | Why |
|---|---|---|
| Fresh-food section | 37 °F (3 °C) | Keeps food below the 40 °F (4 °C) food-safety limit without freezing produce. |
| Freezer | 0 °F (−18 °C) | Stops bacterial growth and preserves texture for long-term storage. |
Change the setting one step at a time and wait 24 hours before adjusting again. An inexpensive appliance thermometer placed in a glass of water on the middle shelf gives the most accurate reading.
Organizing food for even cooling
- Store milk, eggs and raw meat on interior shelves — the door bins are the warmest part of the cabinet.
- Keep raw meat, poultry and fish on the lowest shelf in a sealed container so juices cannot drip onto ready-to-eat food.
- Use the high-humidity crisper for leafy greens and the low-humidity drawer for fruit that releases ethylene, such as apples and pears.
- Do not block the air vents at the back of the compartment; leave a small gap between packages so cold air can circulate.
- Let hot food cool briefly, but refrigerate leftovers within two hours of cooking.
Care and maintenance
| When | What to do |
|---|---|
| Every week | Discard expired food and wipe up spills while they are fresh. |
| Every month | Wash shelves and bins with warm water and mild dish soap; dry thoroughly. Avoid abrasive cleaners on plastic liners. |
| Every 3 months | Check the door gaskets: close the door on a strip of paper — if it slides out easily, clean the gasket or have it replaced. |
| Every 6–12 months | Unplug the unit and vacuum the condenser coils (behind the toe-grille or at the rear) to keep the compressor running efficiently. |
| Before a long absence | Remove food, unplug, clean and dry the interior, and prop the doors open to prevent odor and mold. |
Troubleshooting
Most refrigerator problems can be solved without a service call. Work through the checks below before contacting an authorized technician.
| Problem | Possible cause | What to try |
|---|---|---|
| Fresh-food section is too warm | Control set too warm; vents blocked by food; door not sealing; dirty condenser coils. | Set to 37 °F and wait 24 h; rearrange items away from vents; clean gaskets and check leveling; vacuum the coils. |
| Runs all the time | New unit still pulling down; hot room; frequent door openings; dirty coils. | Allow 24 h after installation; improve ventilation around the cabinet; clean the coils. Modern high-efficiency compressors run longer at lower speed by design. |
| Frost or ice inside the freezer | Door left ajar; worn gasket; humid air entering. | Check that nothing prevents the door from closing; test the gasket with a paper strip; defrost and reseal. |
| Water on the floor | Clogged defrost drain; loose water-supply fitting; drain pan out of place. | Flush the drain with warm water; tighten fittings; reseat the drain pan. |
| Clicking, gurgling or humming sounds | Normal refrigerant flow, defrost heater, fan and valve operation. | These sounds are normal. Loud rattling usually means the cabinet is not level or something is touching the rear tubing. |
| Condensation on the outside of the cabinet | High room humidity; door not fully closed. | Wipe dry; verify the door seals. Some sweating in very humid weather is normal. |
Energy use and running costs
The Summit LTM10W is rated at 296 kWh per year under the U.S. Department of Energy test procedure. At an average electricity price of $0.17 per kWh, that works out to about $50.32 per year, or roughly $4.19 per month.
The federal maximum for this product class is 331 kWh/yr, so this model uses 35 kWh less per year — about $5.95 saved annually, or $71.40 over a typical 12-year service life.
Real-world consumption varies with room temperature, how often the doors are opened, temperature settings and whether the ice maker is in use.
Frequently asked questions
What is the capacity of the Summit LTM10W?
The Summit LTM10W has a total capacity of 10 cubic feet (adjusted volume 12.1 cu. ft., which weights freezer space more heavily for energy calculations).
What are the dimensions of the Summit LTM10W?
It is 59.8 inches high and 23.4 inches wide. Depth is not published in the certification data, so confirm it with the manufacturer's specification sheet before ordering.
How much electricity does the Summit LTM10W use?
It is rated at 296 kWh per year, which costs about $50.32 a year at $0.17/kWh.
Does the Summit LTM10W have an ice maker?
No. The certified configuration does not include an automatic ice maker, so you will need ice trays.
What temperature should I set my Summit refrigerator to?
Set the fresh-food compartment to 37 °F (3 °C) and the freezer to 0 °F (−18 °C). Wait 24 hours after any change before checking the temperature again.
What refrigerant does the Summit LTM10W use?
The certification record lists R-600a (GWP:3 | Lower GWP).
Is the Summit LTM10W ENERGY STAR certified?
Yes. It appears on the ENERGY STAR certified refrigerators list, with a certification date of August 2025, and it also qualifies as ENERGY STAR Most Efficient.
Sources and disclaimer
Specifications on this page come from the ENERGY STAR certified refrigerators dataset published by the U.S. Environmental Protection Agency (record certified August 12, 2025), retrieved October 7, 2026.
The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with Summit. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact Summit or an authorized service provider for warranty repairs and replacement parts.
Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.
Report a problem with this guide
Spotted a wrong value, a broken link or something unclear? Tell us and we will review it.