UPS Battery BackupsMulti-Mode Double-Conversion

APC by Schneider Electric SRTL8KRM4UT UPS Battery Backup Manual

Setup, everyday use, maintenance and troubleshooting for the 8,000 VA / 8,000 W rack-mount multi-mode double-conversion UPS, with verified specifications.

  • Rating8,000 VA / 8,000 W
  • TopologyMulti-Mode Double-Conversion
  • Efficiency96.7%
  • Runtime at half load15 min

About the APC by Schneider Electric SRTL8KRM4UT

APC by Schneider Electric model SRTL8KRM4UT is an 8,000 VA / 8,000 W rack-mount multi-mode double-conversion UPS that meets ENERGY STAR UPS efficiency requirements. It is marketed as the Smart-UPS Ultra On-Line Lithium-ion 8kVA/8kW 4URack/Tower 208/240V.

It can support up to 8,000 W of connected equipment (8,000 VA apparent power, a 1.00 output power factor). It is rated for 208–240 V, 50/60 Hz input. It has 4 outlets, all with battery backup and surge protection. Energy storage is a lithium-ion battery (internal), with a 5-year warranty listed in the certification record.

ENERGY STAR weighted efficiency is 96.7%, and 95.7% at half load. With nothing connected it draws 102 W. Its weighted efficiency is higher than 88% of the 348 Multi-Mode Double-Conversion models in our database.

The manufacturer lists it for commercial applications.

Specifications

APC by Schneider Electric SRTL8KRM4UT specifications
BrandAPC by Schneider Electric
Model numberSRTL8KRM4UT
Model name / seriesSmart-UPS Ultra On-Line Lithium-ion 8kVA/8kW 4URack/Tower 208/240V
TopologyMulti-Mode Double-Conversion
Apparent power rating8,000 VA
Real power rating8,000 W
Output power factor (W/VA)1.00
Default normal modeVFI (voltage and frequency independent)
Multiple normal modesYes
Intended applicationsCommercial
Rated input voltage208–240 V
Rated output voltage208–240 V
Input frequency50/60 Hz
Total outlets4
Battery backup + surge outlets4
Battery technologyLithium-ion
Battery locationInternal
Runtime at full load7 min
Runtime at half load15 min
Battery warranty5 years
Weighted efficiency (ENERGY STAR)96.7%
Efficiency at 25% load93.5%
Efficiency at 50% load95.7%
Efficiency at 75% load96.3%
Efficiency at 100% load96.5%
Input power at no load102.0 W
Input power factor0.99
Rack-mountableYes
Height6.9 in.
Width17.0 in.
Depth28.8 in.
Modular designNo
Communication portsEthernet
Management protocolsHTTP, HTTPS, SNMP
Manufacturer take-back programYes

Safety information

  • Units of this size may require a dedicated circuit, a locking plug or hardwired connection. Have a licensed electrician verify the circuit and receptacle for the 208–240 V input rating before installation.
  • The UPS contains a battery that can deliver dangerous energy even when the unit is unplugged, and its outlets may be live on battery power. Do not open the enclosure except to replace batteries as described in the manual.
  • Install the UPS indoors in a clean, dry, well-ventilated location away from heat sources and direct sunlight. Lithium-ion batteries must be kept within the temperature range in the manual.
  • Battery-equipped UPS units are heavy. Use at least two people (or a lift) to move or rack-mount the unit, and install it in the lowest available rack position to keep the rack stable.

Installation and first-time setup

Size the load first. Add up the wattage of the equipment you plan to protect (check each power supply label or measure it with a plug-in meter). Keep the total below the 8,000 W rating — ideally under about 6,400 W (80%) to leave headroom for start-up surges and battery aging. The 8,000 VA figure is apparent power; the watt rating is the one that limits most modern IT equipment.

  1. Inspect and position

    Unpack the UPS and check for shipping damage. For rack installation, mount the rails and slide the UPS in with a helper; tower units stand upright on a hard floor.

  2. Connect the battery

    Many UPS units ship with the battery disconnected for safety. If so, connect it as shown in the quick-start guide before plugging in.

  3. Connect input power

    Connect the UPS to its dedicated circuit (208–240 V) as specified in the installation manual.

  4. Charge the battery

    Turn the UPS on and let it charge for several hours before relying on full runtime. Equipment can be connected and used during charging, but runtime will be limited until the battery is full.

  5. Connect equipment

    Plug computers, network equipment and storage into the 4 battery-backup outlets.

  6. Set up automatic shutdown

    Connect the Ethernet management port and configure its IP address so servers and administrators can monitor the UPS over HTTP, HTTPS, and SNMP.

  7. Run a self-test

    Once the battery is charged, start a self-test from the front panel or software to confirm that the UPS transfers to battery correctly.

Using your UPS

How this UPS protects your equipment

As an online double-conversion UPS, it continuously converts incoming AC to DC and back to clean AC, so connected equipment is isolated from voltage and frequency disturbances and there is no transfer time when the utility fails. Because it supports multiple normal modes, it can also run in a high-efficiency (eco) mode that passes filtered utility power through when conditions are good and switches back to double conversion when they are not. Its default operating mode is classified as VFI (voltage and frequency independent).

Battery runtime

According to the certification record, the internal battery provides about 7 minutes at full rated load (8,000 W) and about 15 minutes at half load (4,000 W). Runtime is not linear — halving the load usually more than doubles it — and it falls as the battery ages or gets warm. Use the runtime to ride through short outages and to shut systems down cleanly during longer ones.

Monitoring and alerts

The UPS provides Ethernet communication. Supported management protocols include HTTP, HTTPS, and SNMP, so it can integrate with network-management systems. Configure email or SNMP alerts for on-battery, low-battery, overload and replace-battery events.

Alarms and everyday use

  • An intermittent beep usually means the UPS is running on battery. Save your work; if the outage continues, shut down connected equipment before the low-battery alarm.
  • A continuous tone or overload indicator means the connected load is too high. Unplug non-essential devices from the battery outlets.
  • Leave the UPS switched on and plugged in at all times so the battery stays charged.

Care and maintenance

WhenWhat to do
MonthlyCheck the front-panel status or software for alarms, confirm the load percentage, and make sure vents are clear of dust and obstructions.
Every 6 monthsRun a self-test (or confirm the automatic self-test passed). Where supported, perform a runtime calibration during a maintenance window, as it discharges the battery.
At the interval in the manualReplace lithium-ion modules when the UPS reports end of life; they generally last much longer than lead-acid batteries.
AnnuallyCheck for firmware and software updates and confirm that automatic shutdown still works by running a controlled test.
At end of lifeReturn used batteries or the complete unit through the manufacturer's take-back program or a certified battery recycler.

Troubleshooting

Use the front-panel indicators, display messages and event log to narrow down problems. For specific alarm codes, consult the manufacturer's manual or support line.

ProblemPossible causeWhat to try
UPS will not turn onBattery disconnected or deeply discharged; input breaker or fuse open; no utility power.Check the battery connection, verify the outlet or input breaker, and let the UPS charge for several hours before trying again.
Beeps and runs on battery with power presentInput voltage or frequency outside limits; loose input plug; generator power.Check the input connection, try a different circuit, and adjust input sensitivity if the manual permits.
Overload alarmConnected load above the rating; high inrush device on battery outlets.Reduce the load below 8,000 W and move printers or heaters off the UPS.
Short runtime or self-test failureAged or hot battery; battery not fully charged.Charge fully and retest; replace the battery if runtime remains well below the rated figures.
Replace-battery indicator onBattery at end of life.Order the specified replacement battery and replace it as described in the manual (or by service for larger units).
Site wiring fault indicatorMissing ground or reversed hot/neutral in the building wiring.Have a qualified electrician inspect the outlet and wiring before connecting equipment.
Computer does not shut down automaticallyCommunication cable not connected; software not installed or not configured.Connect the USB or serial cable (or configure the network card), install the management software, and test with a simulated outage.
Unexpected transfers in eco modeUtility disturbances causing the UPS to leave high-efficiency mode.Review the event log; if transfers are frequent, consider keeping the UPS in double-conversion mode for that site.

Energy use and running costs

A UPS uses energy as conversion and charging losses on top of what your equipment consumes. The APC by Schneider Electric SRTL8KRM4UT has an ENERGY STAR weighted efficiency of 96.7%. The table estimates its losses if it supports a steady load 24 hours a day, 365 days a year, at $0.17 per kWh.

Losses calculated from the efficiency measured at each load point in the minimum tested configuration.
LoadEfficiencyPower lostLosses per yearCost per year
25% (2,000 W)93.5%139 W1,218 kWh$207
50% (4,000 W)95.7%180 W1,574 kWh$268
75% (6,000 W)96.3%231 W2,019 kWh$343
100% (8,000 W)96.5%290 W2,542 kWh$432

Even with nothing connected, the UPS draws about 102 W to keep its electronics and battery charger running — around 893 kWh ($152) a year.

Running in high-efficiency (eco) mode, where appropriate for your site, reduces these losses further. Loading a UPS very lightly lowers its efficiency, so choosing a unit sized reasonably close to your actual load keeps losses down.

Frequently asked questions

How much equipment can the APC by Schneider Electric SRTL8KRM4UT power?

It is rated at 8,000 W (8,000 VA). Keep the connected load below that — ideally under about 6,400 W — to allow for surges and battery aging.

How long will the APC by Schneider Electric SRTL8KRM4UT run on battery?

The certification record lists 7 minutes at full load and 15 minutes at half load. Lighter loads run longer; older or warm batteries run shorter.

What type of UPS is the APC by Schneider Electric SRTL8KRM4UT?

It uses a multi-mode double-conversion topology and defaults to VFI (voltage and frequency independent) operation. Double conversion gives the highest level of power conditioning with zero transfer time.

How efficient is the APC by Schneider Electric SRTL8KRM4UT?

Its ENERGY STAR weighted efficiency is 96.7%. At half load (4,000 W) it is 95.7% efficient, losing about 180 W — roughly $268 a year if run continuously at $0.17/kWh.

How many outlets does the APC by Schneider Electric SRTL8KRM4UT have?

It has 4 outlets, all of which provide battery backup and surge protection.

What battery does the APC by Schneider Electric SRTL8KRM4UT use?

It uses a lithium-ion battery (internal). The certification record lists a 5-year battery warranty.

Can the APC by Schneider Electric SRTL8KRM4UT be monitored over the network?

Yes. It has an Ethernet connection and supports HTTP, HTTPS, and SNMP.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified ups battery backups dataset published by the U.S. Environmental Protection Agency (record certified December 26, 2023), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with APC by Schneider Electric. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact APC by Schneider Electric or an authorized service provider for warranty repairs and replacement parts.