UPS Battery BackupsMulti-Mode Double-Conversion

Vertiv GXT5-2000LVRT2UXL UPS Battery Backup Manual

Setup, everyday use, maintenance and troubleshooting for the 2,000 VA / 1,800 W rack-mount multi-mode double-conversion UPS, with verified specifications.

  • Rating2,000 VA / 1,800 W
  • TopologyMulti-Mode Double-Conversion
  • Efficiency92.5%
  • Runtime at half load9 min

About the Vertiv GXT5-2000LVRT2UXL

This guide covers the Vertiv GXT5-2000LVRT2UXL, a 2,000 VA / 1,800 W rack-mount multi-mode double-conversion UPS listed as ENERGY STAR certified.

It can support up to 1,800 W of connected equipment (2,000 VA apparent power, a 0.90 output power factor). It is rated for 110–125 V, 50/60 Hz input. Energy storage is a valve-regulated lead-acid (VRLA) battery (separate battery cabinet), with a 2-year warranty listed in the certification record.

ENERGY STAR weighted efficiency is 92.5%, and 92.7% at half load. With nothing connected it draws 27.8 W.

The manufacturer lists it for consumer, commercial, and data center applications.

Specifications

Vertiv GXT5-2000LVRT2UXL specifications
BrandVertiv
Model numberGXT5-2000LVRT2UXL
TopologyMulti-Mode Double-Conversion
Apparent power rating2,000 VA
Real power rating1,800 W
Output power factor (W/VA)0.90
Default normal modeVFI (voltage and frequency independent)
Multiple normal modesYes
Intended applicationsConsumer, Commercial, Data Center
Rated input voltage110–125 V
Rated output voltage110–125 V
Input frequency50/60 Hz
Battery technologyValve-regulated lead-acid (VRLA)
Battery locationSeparate battery cabinet
Runtime at full load3 min
Runtime at half load9 min
Battery warranty2 years
Weighted efficiency (ENERGY STAR)92.5%
Efficiency at 25% load90.9%
Efficiency at 50% load92.7%
Efficiency at 75% load92.4%
Efficiency at 100% load92.3%
Input power at no load27.8 W
Input power factor0.99
Rack-mountableYes
Height3.3 in.
Width16.9 in.
Depth18.5 in.
Modular designNo
Communication portsUSB, Ethernet
Manufacturer take-back programNo

Safety information

  • Plug the UPS directly into a properly grounded wall outlet. Do not plug it into a surge protector, power strip or extension cord, and do not plug a power strip or surge protector into its battery outlets unless the manufacturer explicitly allows it.
  • Do not connect laser printers, space heaters, hair dryers, vacuum cleaners or other high-current appliances to the battery outlets; their surge current can overload the UPS.
  • The UPS contains a battery that can deliver dangerous energy even when the unit is unplugged, and its outlets may be live on battery power. Do not open the enclosure except to replace batteries as described in the manual.
  • Install the UPS indoors in a clean, dry, well-ventilated location away from heat sources and direct sunlight. High temperatures shorten battery life sharply.
  • Battery-equipped UPS units are heavy. Use at least two people (or a lift) to move or rack-mount the unit, and install it in the lowest available rack position to keep the rack stable.

Installation and first-time setup

Size the load first. Add up the wattage of the equipment you plan to protect (check each power supply label or measure it with a plug-in meter). Keep the total below the 1,800 W rating — ideally under about 1,440 W (80%) to leave headroom for start-up surges and battery aging. The 2,000 VA figure is apparent power; the watt rating is the one that limits most modern IT equipment.

  1. Inspect and position

    Unpack the UPS and check for shipping damage. For rack installation, mount the rails and slide the UPS in with a helper; tower units stand upright on a hard floor.

  2. Connect the battery

    Many UPS units ship with the battery disconnected for safety. If so, connect it as shown in the quick-start guide before plugging in.

  3. Connect input power

    Plug the UPS into a grounded wall outlet on a circuit that is not heavily loaded by other equipment.

  4. Charge the battery

    Turn the UPS on and let it charge for several hours before relying on full runtime. Equipment can be connected and used during charging, but runtime will be limited until the battery is full.

  5. Connect equipment

    Plug your computer, monitor, modem and router into the battery-backup outlets (they are usually labeled), keeping within the rated load.

  6. Set up automatic shutdown

    Connect the USB cable from the UPS to the computer and install the manufacturer's power-management software (or use the operating system's built-in UPS support) so it shuts down gracefully before the battery runs out. Connect the Ethernet management port and configure its IP address so servers and administrators can monitor the UPS.

  7. Run a self-test

    Once the battery is charged, start a self-test (usually by holding the power or test button, or from the software) to confirm that the UPS transfers to battery correctly.

Using your UPS

How this UPS protects your equipment

As an online double-conversion UPS, it continuously converts incoming AC to DC and back to clean AC, so connected equipment is isolated from voltage and frequency disturbances and there is no transfer time when the utility fails. Because it supports multiple normal modes, it can also run in a high-efficiency (eco) mode that passes filtered utility power through when conditions are good and switches back to double conversion when they are not. Its default operating mode is classified as VFI (voltage and frequency independent).

Battery runtime

According to the certification record, the tested battery configuration provides about 3 minutes at full rated load (1,800 W) and about 9 minutes at half load (900 W). Runtime is not linear — halving the load usually more than doubles it — and it falls as the battery ages or gets warm. Use the runtime to ride through short outages and to shut systems down cleanly during longer ones.

Monitoring and alerts

The UPS provides USB and Ethernet communication. Configure email or SNMP alerts for on-battery, low-battery, overload and replace-battery events.

Alarms and everyday use

  • An intermittent beep usually means the UPS is running on battery. Save your work; if the outage continues, shut down connected equipment before the low-battery alarm.
  • A continuous tone or overload indicator means the connected load is too high. Unplug non-essential devices from the battery outlets.
  • Leave the UPS switched on and plugged in at all times so the battery stays charged.

Care and maintenance

WhenWhat to do
MonthlyCheck the front-panel status or software for alarms, confirm the load percentage, and make sure vents are clear of dust and obstructions.
Every 6 monthsRun a self-test (or confirm the automatic self-test passed). Where supported, perform a runtime calibration during a maintenance window, as it discharges the battery.
Every 3–5 yearsReplace VRLA batteries. Typical life is 3–5 years at 77 °F (25 °C); roughly every 15 °F (8 °C) above that can cut battery life in half.
AnnuallyCheck for firmware and software updates and confirm that automatic shutdown still works by running a controlled test.

Troubleshooting

Use the front-panel indicators, display messages and event log to narrow down problems. For specific alarm codes, consult the manufacturer's manual or support line.

ProblemPossible causeWhat to try
UPS will not turn onBattery disconnected or deeply discharged; input breaker or fuse open; no utility power.Check the battery connection, verify the outlet or input breaker, and let the UPS charge for several hours before trying again.
Beeps and runs on battery with power presentInput voltage or frequency outside limits; loose input plug; generator power.Check the input connection, try a different circuit, and adjust input sensitivity if the manual permits.
Overload alarmConnected load above the rating; high inrush device on battery outlets.Reduce the load below 1,800 W and move printers or heaters off the UPS.
Short runtime or self-test failureAged or hot battery; battery not fully charged.Charge fully and retest; replace the battery if runtime remains well below the rated figures.
Replace-battery indicator onBattery at end of life.Order the specified replacement battery and replace it as described in the manual (or by service for larger units).
Site wiring fault indicatorMissing ground or reversed hot/neutral in the building wiring.Have a qualified electrician inspect the outlet and wiring before connecting equipment.
Computer does not shut down automaticallyCommunication cable not connected; software not installed or not configured.Connect the USB or serial cable (or configure the network card), install the management software, and test with a simulated outage.
Unexpected transfers in eco modeUtility disturbances causing the UPS to leave high-efficiency mode.Review the event log; if transfers are frequent, consider keeping the UPS in double-conversion mode for that site.

Energy use and running costs

A UPS uses energy as conversion and charging losses on top of what your equipment consumes. The Vertiv GXT5-2000LVRT2UXL has an ENERGY STAR weighted efficiency of 92.5%. The table estimates its losses if it supports a steady load 24 hours a day, 365 days a year, at $0.17 per kWh.

Losses calculated from the efficiency measured at each load point in the minimum tested configuration.
LoadEfficiencyPower lostLosses per yearCost per year
25% (450 W)90.9%45 W395 kWh$67.09
50% (900 W)92.7%70.9 W621 kWh$106
75% (1,350 W)92.4%111 W973 kWh$165
100% (1,800 W)92.3%150 W1,315 kWh$224

Even with nothing connected, the UPS draws about 27.8 W to keep its electronics and battery charger running — around 244 kWh ($41.44) a year.

Running in high-efficiency (eco) mode, where appropriate for your site, reduces these losses further. Loading a UPS very lightly lowers its efficiency, so choosing a unit sized reasonably close to your actual load keeps losses down.

Frequently asked questions

How much equipment can the Vertiv GXT5-2000LVRT2UXL power?

It is rated at 1,800 W (2,000 VA). Keep the connected load below that — ideally under about 1,440 W — to allow for surges and battery aging.

How long will the Vertiv GXT5-2000LVRT2UXL run on battery?

The certification record lists 3 minutes at full load and 9 minutes at half load. Lighter loads run longer; older or warm batteries run shorter.

What type of UPS is the Vertiv GXT5-2000LVRT2UXL?

It uses a multi-mode double-conversion topology and defaults to VFI (voltage and frequency independent) operation. Double conversion gives the highest level of power conditioning with zero transfer time.

How efficient is the Vertiv GXT5-2000LVRT2UXL?

Its ENERGY STAR weighted efficiency is 92.5%. At half load (900 W) it is 92.7% efficient, losing about 70.9 W — roughly $106 a year if run continuously at $0.17/kWh.

What battery does the Vertiv GXT5-2000LVRT2UXL use?

It uses a valve-regulated lead-acid (VRLA) battery (separate battery cabinet). The certification record lists a 2-year battery warranty.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified ups battery backups dataset published by the U.S. Environmental Protection Agency (record certified December 5, 2018), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with Vertiv. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact Vertiv or an authorized service provider for warranty repairs and replacement parts.

Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.