Air King AK100H Ventilation Fan Manual

Setup, everyday use, maintenance and troubleshooting for the 100 CFM bathroom exhaust fan, with verified specifications.

  • Airflow100 CFM
  • Sound2 sones
  • Efficacy3.8 CFM/W
  • Duct size4 in. round

About the Air King AK100H

Air King model AK100H is a 100 CFM bathroom exhaust fan that meets ENERGY STAR efficiency requirements.

It is rated to move 100 cubic feet of air per minute at a single speed. At 0.25 in. of static pressure — closer to a real duct run with elbows and a roof cap — airflow is 83.8 CFM. Its sound rating is 2 sones, which is quiet to moderate — audible, but easy to talk over. It connects to a 4 in. round duct.

Fan efficacy is 3.8 CFM per watt, which means the motor draws roughly 26 W at 100 CFM.

Specifications

Air King AK100H specifications
BrandAir King
Model numberAK100H
Fan typeBathroom & Utility
Rated airflow100 CFM
Fan efficacy3.8 CFM/W
Airflow at 0.25 in. w.g.83.8 CFM
Sound level (highest rated)2.0 sones
Number of speeds1
Duct connection (round)4.0 in.
Integrated lightNo
ENERGY STAR Most EfficientNo

Safety information

  • Turn off power at the circuit breaker before installing, wiring or cleaning the fan, and confirm it is off with a non-contact voltage tester.
  • Install and wire the fan in accordance with the instructions and local electrical and building codes. If you are unsure, hire a licensed electrician or HVAC contractor.
  • Always duct the fan to the outdoors. Never terminate exhaust in an attic, crawl space, soffit vent or wall cavity — trapped moisture and grease cause mold, rot and fire risk.
  • If the fan is installed over a bathtub or shower, it must be listed for that location and is typically required to be on a GFCI-protected circuit — check the installation instructions.
  • Do not use the fan to exhaust explosive or flammable vapors.

Installation and first-time setup

  1. Check the fan size

    For a bathroom up to 100 sq. ft. with an 8 ft ceiling, plan on about 1 CFM per square foot, and at least 50 CFM. At 100 CFM this fan suits a bathroom up to roughly 100 sq. ft. by that rule.

  2. Choose the location

    Mount the fan in the ceiling between the shower and toilet, or as close to the shower as the listing allows, and away from the door so it draws air across the room.

  3. Plan the duct run

    Use 4 in. round smooth metal or insulated flexible duct no smaller than the fan's collar. Keep the run as short and straight as possible, pull flexible duct taut, and slope horizontal runs slightly toward the exterior so condensation drains out.

  4. Insulate and terminate

    In an unheated attic, use insulated duct to prevent condensation. End the run at a roof or wall cap with a backdraft damper — never in the attic or a soffit vent.

  5. Mount and wire

    Fasten the housing to the joists with the supplied brackets, seal the gap between housing and ceiling to stop air leakage, and make the electrical connections inside the wiring box. Attach the grille.

  6. Test

    Restore power and hold a single sheet of tissue near the grille — it should be drawn firmly against it. Check outdoors that the damper opens when the fan runs.

Using your ventilation fan

How long to run the fan

Turn the fan on when you start a bath or shower and leave it running for about 20 minutes afterward to clear moisture from the room and surfaces. A timer switch or humidity-sensing control makes this automatic and prevents the fan from running all day.

Care and maintenance

WhenWhat to do
Every 3–6 monthsRemove the grille (it usually unclips with spring wires), wash it in warm, soapy water and vacuum dust from the housing and fan blades with power off.
Every yearCheck outdoors that the damper flap opens freely and the exterior cap is clear of lint, nests and debris.
Every few yearsInspect accessible duct runs for disconnected joints, crushed sections or condensation.

Troubleshooting

Weak airflow and excess noise are almost always caused by the duct system rather than the fan. Turn off power at the breaker before removing the grille or touching the motor.

ProblemPossible causeWhat to try
Fan runs but moves little airDamper stuck closed; duct crushed, disconnected or too long; dirty grille or filter.Check the exterior damper and cap, inspect the duct, and clean the grille or filters.
Louder than expectedRestrictive or undersized duct; loose grille; housing not secured.Use duct at least as large as the collar (4 in. round), tighten the grille and mounting screws.
Rattling or flapping soundBackdraft damper fluttering in wind; loose duct.Secure the duct and check that the damper closes fully; a wall cap with a better damper may help.
Water dripping from the grilleCondensation in an uninsulated duct; duct sloped back toward the fan.Insulate the duct in unheated spaces and slope it toward the exterior.
Fan will not startBreaker off; switch or timer failed; motor plug loose in the housing.Check the breaker, test the switch, and with power off confirm the motor is plugged into its receptacle.
Cold drafts from the fan when offDamper not closing; unsealed housing.Free or replace the damper and seal around the housing.

Energy use and running costs

Ventilation fan certification lists airflow and efficacy rather than annual energy use. From 100 CFM at 3.8 CFM/W, the Air King AK100H draws roughly 26 W. The table estimates yearly use at an average electricity price of $0.17 per kWh.

ScenarioPowerEnergy per yearCost per year
After showers, 1 h/day26 W9.6 kWh$1.63
Continuous at 100 CFM, 24 h/day26 W231 kWh$39.19

The motor is only part of the cost: every cubic foot exhausted is replaced by outdoor air that must be heated or cooled. Run the fan as long as needed to clear moisture, then let a timer or humidity control switch it off — unless it is providing intended continuous ventilation.

Frequently asked questions

How many CFM is the Air King AK100H?

It is rated at 100 CFM, and delivers 83.8 CFM at 0.25 in. of static pressure.

How loud is the Air King AK100H?

It is rated at 2 sones, which is quiet to moderate — audible, but easy to talk over. Restrictive ductwork can make any fan louder than its rating.

What size duct does the Air King AK100H need?

It has a 4 in. round duct connection. Use duct at least that size all the way to the exterior cap; reducing it cuts airflow and raises noise.

What size bathroom can the Air King AK100H ventilate?

Using the common rule of 1 CFM per square foot for bathrooms up to 100 sq. ft. with 8 ft ceilings, 100 CFM covers a bathroom up to about 100 sq. ft.

How much electricity does the Air King AK100H use?

With an efficacy of 3.8 CFM/W it draws roughly 26 W at 100 CFM. Running one hour a day costs about $1.63 a year at $0.17/kWh.

Does the Air King AK100H have a light?

No. The certified configuration does not include a light.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified ventilation fans dataset published by the U.S. Environmental Protection Agency (record certified January 31, 2016), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with Air King. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact Air King or an authorized service provider for warranty repairs and replacement parts.

Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.