Ventilation FansRange Hood

Broan BCSEK124BL Ventilation Fan Manual

Setup, everyday use, maintenance and troubleshooting for the 150 CFM range hood with light, with verified specifications.

  • Airflow150 CFM
  • Sound1.5 sones
  • Efficacy5.5 CFM/W
  • Duct size7 in. round

About the Broan BCSEK124BL

This guide covers the Broan BCSEK124BL, a 150 CFM range hood with light on the ENERGY STAR certified list.

It has rated airflow settings of 110, 140, and 150 CFM (2-speed). Its sound rating is 1.5 sones, which is quiet to moderate — audible, but easy to talk over. It connects to a 7 in. round duct.

The integrated LED light produces 941 lumens and draws 10 W, with an efficacy of 93.8 lumens per watt, a 3000 K color temperature, and a CRI of 83. It supports continuous dimming.

Fan efficacy is 5.5 CFM per watt, which means the motor draws roughly 27 W at 150 CFM. That efficacy is higher than 68% of the 86 Range Hood models in our database.

Specifications

Broan BCSEK124BL specifications
BrandBroan
Model numberBCSEK124BL
Fan typeRange Hood
Rated airflow150 CFM
Fan efficacy5.5 CFM/W
Second airflow setting140 CFM
Efficacy at second setting5.1 CFM/W
Third airflow setting110 CFM
Efficacy at third setting4.0 CFM/W
Sound level (highest rated)1.5 sones
Number of speeds2
Duct connection (round)7.0 in.
Integrated lightYes
Lighting technologyLED
Light output941 lumens
Light power10.0 W
Luminaire efficacy93.8 lm/W
Color temperature3000 K
Color rendering index (CRI)83
Rated light-source life54,000 hours
Dimmable lightYes
ENERGY STAR Most EfficientNo

Safety information

  • Turn off power at the circuit breaker before installing, wiring or cleaning the fan, and confirm it is off with a non-contact voltage tester.
  • Install and wire the fan in accordance with the instructions and local electrical and building codes. If you are unsure, hire a licensed electrician or HVAC contractor.
  • Always duct the fan to the outdoors. Never terminate exhaust in an attic, crawl space, soffit vent or wall cavity — trapped moisture and grease cause mold, rot and fire risk.
  • Never leave cooking unattended, and keep grease filters clean — grease buildup in the hood or duct is a fire hazard. In a grease fire, turn off the burner and smother the flames with a lid or baking sheet; never use water. If the fire does not go out immediately, leave the house and call the fire department.
  • Do not use the fan to exhaust explosive or flammable vapors.

Installation and first-time setup

  1. Confirm the mounting height

    Install the hood at the height above the cooktop specified in the installation manual — commonly 24–30 in. — to balance capture and head clearance. Gas cooktops often need more clearance than electric.

  2. Check the airflow

    Building codes typically require at least 100 CFM for kitchen exhaust. This hood is rated at 150 CFM (settings of 110, 140, and 150 CFM); heavy cooking or high-output gas burners benefit from more capture.

  3. Route the duct

    Connect the 7 in. round duct with smooth metal duct, sealed with foil tape. Avoid plastic or foil flex duct, keep elbows to a minimum, and terminate at a wall or roof cap with a backdraft damper.

  4. Mount and wire

    Secure the hood to studs or blocking with the supplied hardware and connect power as the wiring diagram shows. Install the grease filters before first use.

  5. Test

    Run each speed and the light, and check outdoors that the damper opens.

Using your range hood

Getting the best capture

Switch the hood on a few minutes before you start cooking so an air current is established, use the rear burners when possible because they sit directly under the hood, and leave it running for 10–15 minutes after cooking to clear lingering moisture and odors.

Use the 110 CFM setting for simmering and everyday cooking, and the 150 CFM setting for frying, searing and other heavy cooking.

Using the light

The integrated LED light produces about 941 lumens from 10 W. It supports continuous dimming; use a dimmer that the manufacturer lists as compatible. The fan and light can usually be wired to separate switches.

Care and maintenance

WhenWhat to do
Every monthRemove the metal grease filters and wash them in hot, soapy water or in the dishwasher if the manual allows. Dry before reinstalling.
Every 3–6 monthsReplace the charcoal filter if the hood is installed in recirculating mode.
Every 3 monthsWipe grease from the hood interior, fan housing and underside with a degreasing cleaner.
Every yearCheck outdoors that the damper flap opens freely and the exterior cap is clear of lint, nests and debris.
As neededClean the light lens. The light source is rated for about 54,000 hours.
Every few yearsInspect accessible duct runs for disconnected joints, crushed sections or condensation.

Troubleshooting

Weak airflow and excess noise are almost always caused by the duct system rather than the fan. Turn off power at the breaker before removing the grille or touching the motor.

ProblemPossible causeWhat to try
Fan runs but moves little airDamper stuck closed; duct crushed, disconnected or too long; dirty grille or filter.Check the exterior damper and cap, inspect the duct, and clean the grille or filters.
Louder than expectedRestrictive or undersized duct; loose grille; housing not secured.Use duct at least as large as the collar (7 in. round), tighten the grille and mounting screws.
Rattling or flapping soundBackdraft damper fluttering in wind; loose duct.Secure the duct and check that the damper closes fully; a wall cap with a better damper may help.
Water dripping from the grilleCondensation in an uninsulated duct; duct sloped back toward the fan.Insulate the duct in unheated spaces and slope it toward the exterior.
Fan will not startBreaker off; switch or timer failed; motor plug loose in the housing.Check the breaker, test the switch, and with power off confirm the motor is plugged into its receptacle.
Cold drafts from the fan when offDamper not closing; unsealed housing.Free or replace the damper and seal around the housing.
Smoke and odors escape the hoodFan started too late; front burners used; filters clogged.Start the hood earlier, cook on rear burners, use a higher speed and clean the filters.
Light flickers or buzzesIncompatible dimmer; loose connector.Use a compatible dimmer or a standard switch, and reseat the light connector with power off.

Energy use and running costs

Ventilation fan certification lists airflow and efficacy rather than annual energy use. From 150 CFM at 5.5 CFM/W, the Broan BCSEK124BL draws roughly 27 W. The table estimates yearly use at an average electricity price of $0.17 per kWh.

ScenarioPowerEnergy per yearCost per year
Cooking, 1 h/day27 W10.0 kWh$1.69
Light on, 3 h/day10 W11.0 kWh$1.87

The motor is only part of the cost: every cubic foot exhausted is replaced by outdoor air that must be heated or cooled. Run the hood while cooking and for 10–15 minutes afterward, then switch it off.

Frequently asked questions

How many CFM is the Broan BCSEK124BL?

It is rated at 150 CFM, with airflow settings of 110, 140, and 150 CFM.

How loud is the Broan BCSEK124BL?

It is rated at 1.5 sones, which is quiet to moderate — audible, but easy to talk over. Restrictive ductwork can make any fan louder than its rating.

What size duct does the Broan BCSEK124BL need?

It has a 7 in. round duct connection. Use duct at least that size all the way to the exterior cap; reducing it cuts airflow and raises noise.

How much electricity does the Broan BCSEK124BL use?

With an efficacy of 5.5 CFM/W it draws roughly 27 W at 150 CFM. Running one hour a day costs about $1.69 a year at $0.17/kWh.

Does the Broan BCSEK124BL have a light?

Yes. It has an integrated light producing about 941 lumens at 3000 K, and it is dimmable.

Can the Broan BCSEK124BL vent into the attic?

No. Range hood exhaust must be ducted to the outdoors through a wall or roof cap with a damper. Venting into an attic or soffit deposits grease and moisture in the building.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified ventilation fans dataset published by the U.S. Environmental Protection Agency (record certified March 23, 2023), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with Broan. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact Broan or an authorized service provider for warranty repairs and replacement parts.

Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.