Ventilation FansIn-Line Single-Port

RadonAway RP140C Ventilation Fan Manual

Setup, everyday use, maintenance and troubleshooting for the 110 CFM in-line ventilation fan, with verified specifications.

  • Airflow110 CFM
  • Efficacy5.9 CFM/W
  • Duct size4 in. round

About the RadonAway RP140C

The RadonAway RP140C is a 110 CFM in-line ventilation fan certified under the ENERGY STAR program. It belongs to the RP line.

It is rated to move 110 cubic feet of air per minute at a single speed. It connects to a 4 in. round duct.

Fan efficacy is 5.9 CFM per watt, which means the motor draws roughly 19 W at 110 CFM. That efficacy is higher than 79% of the 74 In-Line Single-Port models in our database.

Specifications

RadonAway RP140C specifications
BrandRadonAway
Model numberRP140C
Model name / seriesRP
Fan typeIn-Line Single-Port
Rated airflow110 CFM
Fan efficacy5.9 CFM/W
Number of speeds1
Duct connection (round)4.0 in.
Integrated lightNo
ENERGY STAR Most EfficientNo

Safety information

  • Turn off power at the circuit breaker before installing, wiring or cleaning the fan, and confirm it is off with a non-contact voltage tester.
  • Install and wire the fan in accordance with the instructions and local electrical and building codes. If you are unsure, hire a licensed electrician or HVAC contractor.
  • Always duct the fan to the outdoors. Never terminate exhaust in an attic, crawl space, soffit vent or wall cavity — trapped moisture and grease cause mold, rot and fire risk.
  • Mount the in-line fan to solid framing in an accessible location so it can be inspected and serviced, and keep it away from insulation that could block the motor housing.
  • Do not use the fan to exhaust explosive or flammable vapors.

Installation and first-time setup

  1. Plan the system

    In-line fans mount in the duct run — usually in an attic or basement — away from living spaces, which keeps them quiet. This single-port model connects to one intake duct, which can be fed by one or more grilles.

  2. Mount the fan

    Fasten the fan to framing with the supplied brackets, using vibration isolators if provided, and leave access for service.

  3. Connect the ducts

    Attach 4 in. round duct to the inlet and outlet collars with clamps or foil tape, observing the airflow arrow on the housing. Use insulated duct through unconditioned spaces.

  4. Wire the controls

    Connect power and the wall control, timer or humidity control specified by the manufacturer. Many in-line fans are used for continuous whole-house ventilation at a low setting.

  5. Test

    Run the fan and confirm airflow at each intake grille and that the exterior damper opens.

Using your ventilation fan

Continuous and boost operation

In-line fans are often run continuously at a low setting for whole-house ventilation, with a boost to a higher setting from a timer or humidity control when bathrooms are in use.

Care and maintenance

WhenWhat to do
Every 3–6 monthsRemove the grille (it usually unclips with spring wires), wash it in warm, soapy water and vacuum dust from the housing and fan blades with power off.
Every yearCheck outdoors that the damper flap opens freely and the exterior cap is clear of lint, nests and debris.
Every few yearsInspect accessible duct runs for disconnected joints, crushed sections or condensation.

Troubleshooting

Weak airflow and excess noise are almost always caused by the duct system rather than the fan. Turn off power at the breaker before removing the grille or touching the motor.

ProblemPossible causeWhat to try
Fan runs but moves little airDamper stuck closed; duct crushed, disconnected or too long; dirty grille or filter.Check the exterior damper and cap, inspect the duct, and clean the grille or filters.
Louder than expectedRestrictive or undersized duct; loose grille; housing not secured.Use duct at least as large as the collar (4 in. round), tighten the grille and mounting screws.
Rattling or flapping soundBackdraft damper fluttering in wind; loose duct.Secure the duct and check that the damper closes fully; a wall cap with a better damper may help.
Water dripping from the grilleCondensation in an uninsulated duct; duct sloped back toward the fan.Insulate the duct in unheated spaces and slope it toward the exterior.
Fan will not startBreaker off; switch or timer failed; motor plug loose in the housing.Check the breaker, test the switch, and with power off confirm the motor is plugged into its receptacle.
Cold drafts from the fan when offDamper not closing; unsealed housing.Free or replace the damper and seal around the housing.

Energy use and running costs

Ventilation fan certification lists airflow and efficacy rather than annual energy use. From 110 CFM at 5.9 CFM/W, the RadonAway RP140C draws roughly 19 W. The table estimates yearly use at an average electricity price of $0.17 per kWh.

ScenarioPowerEnergy per yearCost per year
Boost, 2 h/day19 W13.6 kWh$2.31
Continuous at 110 CFM, 24 h/day19 W163 kWh$27.76

The motor is only part of the cost: every cubic foot exhausted is replaced by outdoor air that must be heated or cooled. Run the fan as long as needed to clear moisture, then let a timer or humidity control switch it off — unless it is providing intended continuous ventilation.

Frequently asked questions

How many CFM is the RadonAway RP140C?

It is rated at 110 CFM.

What size duct does the RadonAway RP140C need?

It has a 4 in. round duct connection. Use duct at least that size all the way to the exterior cap; reducing it cuts airflow and raises noise.

How much electricity does the RadonAway RP140C use?

With an efficacy of 5.9 CFM/W it draws roughly 19 W at 110 CFM. Running one hour a day costs about $1.16 a year at $0.17/kWh.

Does the RadonAway RP140C have a light?

No. The certified configuration does not include a light.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified ventilation fans dataset published by the U.S. Environmental Protection Agency (record certified March 20, 2025), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with RadonAway. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact RadonAway or an authorized service provider for warranty repairs and replacement parts.

Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.