Ventilation FansBathroom & Utility

Utilitech 7116-02 Ventilation Fan Manual

Setup, everyday use, maintenance and troubleshooting for the 150 CFM bathroom exhaust fan with light, with verified specifications.

  • Airflow150 CFM
  • Sound1 sone
  • Efficacy8.1 CFM/W
  • Duct size6 in. round

About the Utilitech 7116-02

The Utilitech 7116-02 is a 150 CFM bathroom exhaust fan with light certified under the ENERGY STAR program.

It is rated to move 150 cubic feet of air per minute at a single speed. At 0.25 in. of static pressure — closer to a real duct run with elbows and a roof cap — airflow is 124 CFM. Its sound rating is 1 sone, which is very quiet — about the level of a quiet refrigerator or less. It connects to a 6 in. round duct.

The integrated LED light produces 1,189 lumens, with an efficacy of 94.3 lumens per watt, a 3000 K color temperature, and a CRI of 82. It is not dimmable.

Fan efficacy is 8.1 CFM per watt, which means the motor draws roughly 19 W at 150 CFM. That efficacy is higher than 67% of the 822 Bathroom & Utility models in our database.

Specifications

Utilitech 7116-02 specifications
BrandUtilitech
Model number7116-02
Fan typeBathroom & Utility
Rated airflow150 CFM
Fan efficacy8.1 CFM/W
Airflow at 0.25 in. w.g.123.8 CFM
Sound level (highest rated)1.0 sones
Sound level at 0.25 in. w.g.1.5 sones
Number of speeds1
Duct connection (round)6.0 in.
Integrated lightYes
Lighting technologyLED
Light output1,189 lumens
Luminaire efficacy94.3 lm/W
Color temperature3000 K
Color rendering index (CRI)82
Rated light-source life59,000 hours
Dimmable lightNo
ENERGY STAR Most EfficientNo

Safety information

  • Turn off power at the circuit breaker before installing, wiring or cleaning the fan, and confirm it is off with a non-contact voltage tester.
  • Install and wire the fan in accordance with the instructions and local electrical and building codes. If you are unsure, hire a licensed electrician or HVAC contractor.
  • Always duct the fan to the outdoors. Never terminate exhaust in an attic, crawl space, soffit vent or wall cavity — trapped moisture and grease cause mold, rot and fire risk.
  • If the fan is installed over a bathtub or shower, it must be listed for that location and is typically required to be on a GFCI-protected circuit — check the installation instructions.
  • Do not use the fan to exhaust explosive or flammable vapors.

Installation and first-time setup

  1. Check the fan size

    For a bathroom up to 100 sq. ft. with an 8 ft ceiling, plan on about 1 CFM per square foot, and at least 50 CFM. At 150 CFM this fan suits a bathroom up to roughly 100 sq. ft. by that rule; for larger bathrooms, allow about 50 CFM per toilet, shower and tub (100 CFM for a jetted tub).

  2. Choose the location

    Mount the fan in the ceiling between the shower and toilet, or as close to the shower as the listing allows, and away from the door so it draws air across the room.

  3. Plan the duct run

    Use 6 in. round smooth metal or insulated flexible duct no smaller than the fan's collar. Keep the run as short and straight as possible, pull flexible duct taut, and slope horizontal runs slightly toward the exterior so condensation drains out.

  4. Insulate and terminate

    In an unheated attic, use insulated duct to prevent condensation. End the run at a roof or wall cap with a backdraft damper — never in the attic or a soffit vent.

  5. Mount and wire

    Fasten the housing to the joists with the supplied brackets, seal the gap between housing and ceiling to stop air leakage, and make the electrical connections inside the wiring box. Attach the grille.

  6. Test

    Restore power and hold a single sheet of tissue near the grille — it should be drawn firmly against it. Check outdoors that the damper opens when the fan runs.

Using your ventilation fan

How long to run the fan

Turn the fan on when you start a bath or shower and leave it running for about 20 minutes afterward to clear moisture from the room and surfaces. A timer switch or humidity-sensing control makes this automatic and prevents the fan from running all day.

Using the light

The integrated LED light produces about 1,189 lumens. The light is not dimmable, so do not connect it to a dimmer switch. The fan and light can usually be wired to separate switches.

Care and maintenance

WhenWhat to do
Every 3–6 monthsRemove the grille (it usually unclips with spring wires), wash it in warm, soapy water and vacuum dust from the housing and fan blades with power off.
Every yearCheck outdoors that the damper flap opens freely and the exterior cap is clear of lint, nests and debris.
As neededClean the light lens. The light source is rated for about 59,000 hours.
Every few yearsInspect accessible duct runs for disconnected joints, crushed sections or condensation.

Troubleshooting

Weak airflow and excess noise are almost always caused by the duct system rather than the fan. Turn off power at the breaker before removing the grille or touching the motor.

ProblemPossible causeWhat to try
Fan runs but moves little airDamper stuck closed; duct crushed, disconnected or too long; dirty grille or filter.Check the exterior damper and cap, inspect the duct, and clean the grille or filters.
Louder than expectedRestrictive or undersized duct; loose grille; housing not secured.Use duct at least as large as the collar (6 in. round), tighten the grille and mounting screws.
Rattling or flapping soundBackdraft damper fluttering in wind; loose duct.Secure the duct and check that the damper closes fully; a wall cap with a better damper may help.
Water dripping from the grilleCondensation in an uninsulated duct; duct sloped back toward the fan.Insulate the duct in unheated spaces and slope it toward the exterior.
Fan will not startBreaker off; switch or timer failed; motor plug loose in the housing.Check the breaker, test the switch, and with power off confirm the motor is plugged into its receptacle.
Cold drafts from the fan when offDamper not closing; unsealed housing.Free or replace the damper and seal around the housing.
Light flickers or buzzesIncompatible dimmer; loose connector.Use a compatible dimmer or a standard switch, and reseat the light connector with power off.

Energy use and running costs

Ventilation fan certification lists airflow and efficacy rather than annual energy use. From 150 CFM at 8.1 CFM/W, the Utilitech 7116-02 draws roughly 19 W. The table estimates yearly use at an average electricity price of $0.17 per kWh.

ScenarioPowerEnergy per yearCost per year
After showers, 1 h/day19 W6.8 kWh$1.15
Continuous at 150 CFM, 24 h/day19 W162 kWh$27.58

The motor is only part of the cost: every cubic foot exhausted is replaced by outdoor air that must be heated or cooled. Run the fan as long as needed to clear moisture, then let a timer or humidity control switch it off — unless it is providing intended continuous ventilation.

Frequently asked questions

How many CFM is the Utilitech 7116-02?

It is rated at 150 CFM, and delivers 124 CFM at 0.25 in. of static pressure.

How loud is the Utilitech 7116-02?

It is rated at 1 sone (1.5 sones at 0.25 in. of static pressure), which is very quiet — about the level of a quiet refrigerator or less. Restrictive ductwork can make any fan louder than its rating.

What size duct does the Utilitech 7116-02 need?

It has a 6 in. round duct connection. Use duct at least that size all the way to the exterior cap; reducing it cuts airflow and raises noise.

What size bathroom can the Utilitech 7116-02 ventilate?

Using the common rule of 1 CFM per square foot for bathrooms up to 100 sq. ft. with 8 ft ceilings, 150 CFM covers a bathroom up to about 100 sq. ft. For larger bathrooms, allow about 50 CFM per fixture (toilet, shower, tub).

How much electricity does the Utilitech 7116-02 use?

With an efficacy of 8.1 CFM/W it draws roughly 19 W at 150 CFM. Running one hour a day costs about $1.15 a year at $0.17/kWh.

Does the Utilitech 7116-02 have a light?

Yes. It has an integrated light producing about 1,189 lumens at 3000 K; it is not dimmable.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified ventilation fans dataset published by the U.S. Environmental Protection Agency (record certified November 9, 2017), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with Utilitech. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact Utilitech or an authorized service provider for warranty repairs and replacement parts.

Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.