Setup, everyday use, maintenance and troubleshooting for the 194,000 Btu/h gas tankless water heater, with verified specifications.
- UEF0.95
- Gas input194,000 Btu/h
About the Glow Brand T180
The Glow Brand T180 is a 194,000 Btu/h gas tankless water heater certified under the ENERGY STAR program.
Its UEF of 0.95 is a level reached only by condensing tankless designs, which recover heat from the exhaust and therefore need plastic venting and a condensate drain.
Specifications
| Brand | Glow Brand |
|---|---|
| Model number | T180 |
| Water heater type | Gas Tankless |
| Fuel / energy source | Natural gas or propane |
| Uniform Energy Factor (UEF) | 0.95 |
| Gas input rate | 194,000 Btu/h |
| Recovery efficiency | 94.4% |
| Maximum current | 15.0 A |
| Connected / demand-response capable | No |
Safety information
- Set the water heater to about 120 °F (49 °C). Water at 140 °F can cause a serious burn in a few seconds; at 120 °F it takes several minutes. Homes with young children or older adults benefit from anti-scald valves at tubs and showers.
- A pressure relief valve must be installed as the manual and local code require. Never cap or plug it.
- Installation should be done by a licensed plumber (and electrician or gas fitter where required). Most jurisdictions require a permit.
- Install carbon monoxide alarms on every level of the home and near sleeping areas, and keep the vent and air-intake terminations clear of snow, leaves and nests.
- If you smell gas, do not operate switches or appliances; leave the building and call your gas utility or 911 from outside.
- Never store gasoline, solvents or other flammable products near the water heater.
- Turn off the 120 V power and the gas valve before opening the cabinet; internal parts can stay hot after use.
Installation and first-time setup
Use this checklist when planning the installation of the Glow Brand T180 and when reviewing the finished job with your installer.
- Size the gas supply
At 194,000 Btu/h this heater needs far more gas at full fire than a typical tank. The gas line and meter must be sized for the full input; an existing 1/2 in. line is often too small.
- Venting
Vent exactly as the manual specifies, observing maximum lengths and termination clearances from windows, doors and grade.
- Condensate drain
Route condensate to a drain through a neutralizer if the manufacturer or local code calls for one.
- Service valves and water quality
Install isolation valves with flush ports so the heat exchanger can be descaled. In hard-water areas, consider a softener or scale-prevention system as the manufacturer recommends.
- Electrical
Provide a grounded 120 V receptacle or circuit (maximum current 15.0 A). The heater needs power for its controls, fan and freeze protection, so it will not make hot water during a power outage.
- Fill and purge before start-up
Open a hot tap to purge air from the lines before turning on gas and power, then set the temperature and check for leaks.
Using your water heater
Flow rate and temperature rise
A brief burst of cooler water after quickly turning a tap off and on again is normal. If you want instant hot water at distant fixtures, ask about a recirculation system compatible with this model.
Saving hot water and energy
- Fix dripping hot-water taps promptly and use WaterSense showerheads and faucet aerators.
- Insulate the first several feet of hot and cold pipes at the heater.
- Wash laundry in cold water when possible.
Care and maintenance
| When | What to do |
|---|---|
| Every year (more often in hard water) | Flush the heat exchanger with a descaling solution through the service valves, following the manufacturer's procedure. |
| Every few months | Clean the cold-water inlet filter screen. |
| Every year | Have the burner, venting, condensate system and neutralizer inspected. |
| Every month | Test carbon monoxide alarms. |
Troubleshooting
Check these common causes before calling for service.
| Problem | Possible cause | What to try |
|---|---|---|
| Water not getting hot at low flow | Flow below the activation threshold; partially closed valve; clogged inlet screen. | Open the tap further; clean the inlet filter. |
| Hot water fluctuates or turns cold in winter | Demand exceeds capacity for the colder incoming water; scale buildup. | Reduce simultaneous uses; schedule descaling. |
| No hot water at all | No power; gas valve closed; ignition failure; error lockout. | Check power and the gas valve; note any code and consult your manufacturer's manual before resetting. |
| Error code on the display | The control detected an ignition, venting, flow or temperature fault. | Look up the code in your manufacturer's manual; venting and gas faults need a technician. |
| Relief valve dripping or discharging | Excess pressure from thermal expansion; failing valve; temperature set too high. | Have the pressure checked and an expansion tank added if needed; replace a faulty valve. Never plug it. |
Frequently asked questions
What is the UEF of the Glow Brand T180?
Its Uniform Energy Factor is 0.95. Higher is better; compare UEF only between models in the same draw pattern.
Does the Glow Brand T180 need electricity?
Yes. It needs a 120 V supply (up to 15.0 A) for its controls, combustion fan and freeze protection, so it cannot make hot water during a power outage.
How often should the Glow Brand T180 be descaled?
Flush the heat exchanger at least once a year, and more often in hard-water areas or if the unit reports a scale warning. Follow the descaling procedure in the manufacturer's manual using the service valves on the water connections.
Is the Glow Brand T180 ENERGY STAR certified?
Yes. It appears on the ENERGY STAR certified water heater list, with a certification date of October 2022.
Sources and disclaimer
Specifications on this page come from the ENERGY STAR certified water heaters dataset published by the U.S. Environmental Protection Agency (record certified October 27, 2022), retrieved October 7, 2026.
The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with Glow Brand. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact Glow Brand or an authorized service provider for warranty repairs and replacement parts.
Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.
Report a problem with this guide
Spotted a wrong value, a broken link or something unclear? Tell us and we will review it.