Water HeatersGas Tankless

State GTS-340X3-NIH 1 Water Heater Manual

Setup, everyday use, maintenance and troubleshooting for the 180,000 Btu/h natural gas tankless water heater, with verified specifications.

  • UEF0.95
  • Max flow5.4 gpm
  • Gas input180,000 Btu/h
  • Est. yearly cost$267

About the State GTS-340X3-NIH 1

The State GTS-340X3-NIH 1 (T-H3S-DV-N) is a 180,000 Btu/h natural gas tankless water heater certified under the ENERGY STAR program.

It is rated to deliver up to 5.4 gallons per minute with a 67 °F temperature rise from a maximum gas input of 180,000 Btu/h, and it starts heating at flows as low as 1.0 gpm. In practice that covers about two simultaneous 2.0 gpm showers when incoming water is around 58 °F; colder winter water reduces the flow it can heat (see Using your water heater). The DOE classifies it in the high usage draw pattern, so its efficiency rating assumes about 84 gallons of hot water a day.

Its UEF of 0.95 is a level reached only by condensing tankless designs, which recover heat from the exhaust and therefore need plastic venting and a condensate drain.

It can be installed as a power direct vent unit with 3 in. vent pipe.

Specifications

State GTS-340X3-NIH 1 specifications
BrandState
Model numberGTS-340X3-NIH 1**
Model name / seriesT-H3S-DV-N
Water heater typeGas Tankless
Fuel / energy sourceNatural gas
Maximum flow (67 °F rise)5.4 gpm
Minimum activation flow1.0 gpm
DOE draw patternHigh-Usage
Uniform Energy Factor (UEF)0.95
Estimated annual natural gas use178 therms/yr
Estimated annual propane use195 gal./yr
Gas input rate180,000 Btu/h
Maximum current5.0 A
Unit height22.0 in.
Unit width18.0 in.
Unit depth11.0 in.
VentingPower direct vent
Vent pipe diameter3 in.
Connected / demand-response capableNo

Safety information

  • Set the water heater to about 120 °F (49 °C). Water at 140 °F can cause a serious burn in a few seconds; at 120 °F it takes several minutes. Homes with young children or older adults benefit from anti-scald valves at tubs and showers.
  • A pressure relief valve must be installed as the manual and local code require. Never cap or plug it.
  • Installation should be done by a licensed plumber (and electrician or gas fitter where required). Most jurisdictions require a permit.
  • Install carbon monoxide alarms on every level of the home and near sleeping areas, and keep the vent and air-intake terminations clear of snow, leaves and nests.
  • If you smell gas, do not operate switches or appliances; leave the building and call your gas utility or 911 from outside.
  • Never store gasoline, solvents or other flammable products near the water heater.
  • Turn off the 120 V power and the gas valve before opening the cabinet; internal parts can stay hot after use.

Installation and first-time setup

Use this checklist when planning the installation of the State GTS-340X3-NIH 1 and when reviewing the finished job with your installer.

  1. Size the gas supply

    At 180,000 Btu/h this heater needs far more gas at full fire than a typical tank. The gas line and meter must be sized for the full input; an existing 1/2 in. line is often too small.

  2. Venting

    Vent exactly as the manual specifies for power direct vent configurations using 3 in. pipe, observing maximum lengths and termination clearances from windows, doors and grade.

  3. Condensate drain

    Route condensate to a drain through a neutralizer if the manufacturer or local code calls for one.

  4. Service valves and water quality

    Install isolation valves with flush ports so the heat exchanger can be descaled. In hard-water areas, consider a softener or scale-prevention system as the manufacturer recommends.

  5. Electrical

    Provide a grounded 120 V receptacle or circuit (maximum current 5.0 A). The heater needs power for its controls, fan and freeze protection, so it will not make hot water during a power outage.

  6. Fill and purge before start-up

    Open a hot tap to purge air from the lines before turning on gas and power, then set the temperature and check for leaks.

Using your water heater

Flow rate and temperature rise

Approximate maximum flow at a 125 °F setpoint, scaled from the 5.4 gpm rating. Actual output varies with gas pressure and altitude.
Incoming waterTemperature riseMax flow
58 °F (rating condition)67 °Fabout 5.4 gpm
45 °F (cool climate in winter)80 °Fabout 4.5 gpm
35 °F (cold northern winter)90 °Fabout 4.0 gpm

The burner lights only when flow exceeds about 1.0 gpm, so a barely open tap may run cold. A brief burst of cooler water after quickly turning a tap off and on again is normal. If you want instant hot water at distant fixtures, ask about a recirculation system compatible with this model.

Saving hot water and energy

  • Fix dripping hot-water taps promptly and use WaterSense showerheads and faucet aerators.
  • Insulate the first several feet of hot and cold pipes at the heater.
  • Wash laundry in cold water when possible.

Care and maintenance

WhenWhat to do
Every year (more often in hard water)Flush the heat exchanger with a descaling solution through the service valves, following the manufacturer's procedure.
Every few monthsClean the cold-water inlet filter screen.
Every yearHave the burner, venting, condensate system and neutralizer inspected.
Every monthTest carbon monoxide alarms.

Troubleshooting

Check these common causes before calling for service.

ProblemPossible causeWhat to try
Water not getting hot at low flowFlow below the activation threshold; partially closed valve; clogged inlet screen.Open the tap further; clean the inlet filter.
Hot water fluctuates or turns cold in winterDemand exceeds capacity for the colder incoming water; scale buildup.Reduce simultaneous uses; schedule descaling.
No hot water at allNo power; gas valve closed; ignition failure; error lockout.Check power and the gas valve; note any code and consult your manufacturer's manual before resetting.
Error code on the displayThe control detected an ignition, venting, flow or temperature fault.Look up the code in your manufacturer's manual; venting and gas faults need a technician.
Relief valve dripping or dischargingExcess pressure from thermal expansion; failing valve; temperature set too high.Have the pressure checked and an expansion tank added if needed; replace a faulty valve. Never plug it.

Energy use and running costs

On natural gas, the State GTS-340X3-NIH 1 is estimated to use 178 therms per year, about $267 a year at $1.50 per therm.

A basic gas storage water heater with a UEF of about 0.60 would burn roughly 282 therms for the same hot water — about $156 more per year.

These estimates come from the DOE test, which assumes 84 gallons of hot water a day heated from 58 °F to 125 °F; your use will differ. The controls, fan and freeze protection also use a small amount of electricity, not included here.

Frequently asked questions

How much hot water can the State GTS-340X3-NIH 1 supply?

It is rated for up to 5.4 gallons per minute at a 67 °F temperature rise (maximum input 180,000 Btu/h). With 45 °F winter water and a 125 °F setpoint, expect about 4.5 gpm.

What is the UEF of the State GTS-340X3-NIH 1?

Its Uniform Energy Factor is 0.95, measured in the DOE high usage draw pattern. Higher is better; compare UEF only between models in the same draw pattern.

How much does it cost to run the State GTS-340X3-NIH 1?

About $267 a year on natural gas, based on its estimated 178 therms/yr at $1.50/therm.

What venting does the State GTS-340X3-NIH 1 use?

It can be installed as a power direct vent unit with 3 in. vent pipe. Follow the installation manual for approved materials and maximum lengths.

Does the State GTS-340X3-NIH 1 need electricity?

Yes. It needs a 120 V supply (up to 5.0 A) for its controls, combustion fan and freeze protection, so it cannot make hot water during a power outage.

How often should the State GTS-340X3-NIH 1 be descaled?

Flush the heat exchanger at least once a year, and more often in hard-water areas or if the unit reports a scale warning. Follow the descaling procedure in the manufacturer's manual using the service valves on the water connections.

Is the State GTS-340X3-NIH 1 ENERGY STAR certified?

Yes. It appears on the ENERGY STAR certified water heater list, with a certification date of February 2023.

Sources and disclaimer

Specifications on this page come from the ENERGY STAR certified water heaters dataset published by the U.S. Environmental Protection Agency (record certified February 22, 2023), retrieved October 7, 2026.

The setup, operating, maintenance and troubleshooting guidance is written by ManualHarbor's editors for this specific product type and configuration. It is an independent guide — not a reproduction of the manufacturer's manual — and ManualHarbor is not affiliated with State. Always follow the safety instructions, installation requirements and warranty terms supplied with your unit, and contact State or an authorized service provider for warranty repairs and replacement parts.

Running-cost figures use assumed U.S. average utility prices and are estimates for comparison only. See our editorial methodology for details.